Praziquantel on Lux 5µm Cellulose-1 by SFC
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.25% IPA + 0.25% TFA) 90:10 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Katrijn De Klerck, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >1.5 SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Praziquantel
- 2. Praziquantel
-OEChem-06211003152D<br><br> 47 50 0 1 0 0 0 0 0999 V2000<br> 4.6077 1.7568 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3856 -2.3019 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2679 -0.7673 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4679 0.2535 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2679 0.2327 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7359 0.2602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3740 0.7673 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8718 0.7635 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.7398 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6038 0.7568 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0038 0.2668 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8641 -1.2365 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1340 0.7327 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1340 -1.2673 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4679 -0.7881 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.7332 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0000 -0.7673 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3740 -1.3020 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0000 0.2327 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1179 1.7742 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9100 0.7395 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0159 2.3019 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9180 1.7811 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2727 0.8526 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2716 -0.0519 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7786 1.2371 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9804 1.2464 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2722 1.2369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4751 1.2400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9418 -1.3233 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3430 -0.6345 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7940 0.8503 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3929 0.1615 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4637 -1.7099 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2608 -1.7130 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7354 -1.7423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5325 -1.7423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8571 -0.6821 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2589 -1.3718 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3898 -0.6231 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7857 -1.3150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.2120 -1.3499 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.6106 -0.6597 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5774 2.0779 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.4433 0.4233 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0136 2.9219 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.4561 2.0890 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 10 2 0 0 0 0<br> 2 18 2 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 14 1 0 0 0 0<br> 3 18 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 4 15 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 13 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 25 1 0 0 0 0<br> 7 26 1 0 0 0 0<br> 7 27 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 8 28 1 0 0 0 0<br> 8 29 1 0 0 0 0<br> 9 12 1 0 0 0 0<br> 9 30 1 0 0 0 0<br> 9 31 1 0 0 0 0<br> 11 16 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 11 33 1 0 0 0 0<br> 12 16 1 0 0 0 0<br> 12 34 1 0 0 0 0<br> 12 35 1 0 0 0 0<br> 13 19 1 0 0 0 0<br> 13 20 2 0 0 0 0<br> 14 17 1 0 0 0 0<br> 14 36 1 0 0 0 0<br> 14 37 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 38 1 0 0 0 0<br> 15 39 1 0 0 0 0<br> 16 40 1 0 0 0 0<br> 16 41 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 17 42 1 0 0 0 0<br> 17 43 1 0 0 0 0<br> 19 21 2 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 44 1 0 0 0 0<br> 21 23 1 0 0 0 0<br> 21 45 1 0 0 0 0<br> 22 23 2 0 0 0 0<br> 22 46 1 0 0 0 0<br> 23 47 1 0 0 0 0<br>M END
Compound Name
Praziquantel
CID
4891
Molecular Formula
C19H24N2O2
Molecular Weight
312
No. Hydrogen Bond Acceptors
2
Similar Applications
Chiral
Praziquantel on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23342
Chiral
Praziquantel on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23325
Chiral
Praziquantel Resolution vs. Flow on Lux Cellulose-1 5um 150 x 4.6 mm
Lux 5 µm Cellulose-1, LC Column 150 x 4.6 mm, Ea
21923
Chiral
Praziquantel on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21326
Chiral
Praziquantel on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21325
Chiral
Praziquantel on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21324
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21323
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21322
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21321
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21320
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21319
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21318
Chiral
Praziquantel on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21317
Praziquantel on Lux 5µm Amylose-2 by SFC
21316
Chiral
Praziquantel on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20542
Chiral
Praziquantel on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20263
Chiral
Praziquantel on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20234
Chiral
Praziquantel on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20147
Chiral
RP Enantioseparation of Praziquantel on Lux Cellulose-2
Lux 3 µm Cellulose-2, LC Column 150 x 2 mm, Ea
19415