Warfarin on LUX 5u Amylose-1 250x4.6mm in PO
LC Conditions
Column
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
Brand
Lux
Part No
00G-4732-E0
Phase Name
Amylose-1
Elution Type
Isocratic
Mobile Phase
A: 0.1% Acetic acid in EtOH
Gradient Profile
Step No.
Time(min)
%A
%B
1
8
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Warfarin
- 2. Warfarin
-OEChem-06211003152D<br><br> 39 41 0 1 0 0 0 0 0999 V2000<br> 6.3301 1.9400 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.9400 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.0600 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0600 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.0600 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0901 -0.0947 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.9400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0901 1.9747 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9962 0.4192 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9962 1.4608 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -1.6426 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -0.9523 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.6800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 1.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0829 -0.7146 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1120 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.1800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3520 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0829 2.5946 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 1.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5319 0.1071 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5319 1.7729 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 10 1 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 10 1 0 0 0 0<br> 2 39 1 0 0 0 0<br> 3 9 2 0 0 0 0<br> 4 12 2 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 10 2 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 25 1 0 0 0 0<br> 7 26 1 0 0 0 0<br> 8 13 2 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 11 15 1 0 0 0 0<br> 11 16 2 0 0 0 0<br> 12 19 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 27 1 0 0 0 0<br> 14 18 2 0 0 0 0<br> 14 28 1 0 0 0 0<br> 15 20 2 0 0 0 0<br> 16 22 1 0 0 0 0<br> 16 29 1 0 0 0 0<br> 17 21 2 0 0 0 0<br> 17 30 1 0 0 0 0<br> 18 21 1 0 0 0 0<br> 18 31 1 0 0 0 0<br> 19 32 1 0 0 0 0<br> 19 33 1 0 0 0 0<br> 19 34 1 0 0 0 0<br> 20 23 1 0 0 0 0<br> 20 35 1 0 0 0 0<br> 21 36 1 0 0 0 0<br> 22 23 2 0 0 0 0<br> 22 37 1 0 0 0 0<br> 23 38 1 0 0 0 0<br>M END
Compound Name
Warfarin
CID
6691
Molecular Formula
C19H16O4
Molecular Weight
308
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
1
Similar Applications
Chiralpak-IG Separation for Warfarin
25364
Chiral
Warfarin on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23308
Chiral
Warfarin on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23303
Chiral
Warfarin on LUX 5u Amylose-1 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23165
Reversed Phase
Pharmaceutical Mix on Kinetex 1.7 F5 50x2.1mm
Kinetex 1.7 µm F5 100 Å, LC Column 50 x 2.1 mm, Ea
22813
Chiral
Normal Phase Loading Study for Warfarin on Lux 5um Cellulose-1 150x4.6
Lux 5 µm Cellulose-1, LC Column 150 x 4.6 mm, Ea
21922
Chiral
Normal Phase Loading Study for Warfarin on Lux 5um Cellulose-1 150x21.2 - AXIA
Lux 5 µm Cellulose-1, LC Column 150 x 21.2 mm, AXIA Packed, Ea
21921
Chiral
SFC Loading Study for Warfarin on Lux 5um Cellulose-1 150x21.2 - AXIA
Lux 5 µm Cellulose-1, LC Column 150 x 21.2 mm, AXIA Packed, Ea
21918
Chiral
SFC Loading Study for Warfarin on Lux 5um Cellulose-1 150x4.6
Lux 5 µm Cellulose-1, LC Column 150 x 4.6 mm, Ea
21917
Chiral
Warfarin on Lux 5 um Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21865
Chiral
Warfarin on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21422
Chiral
Warfarin on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21421
Chiral
Warfarin on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21420
Warfarin on Lux 5µm Amylose-2 in NP
20508
Chiral
Warfarin on Lux 5µm Cellulose-3 in PO
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20360
Chiral
Warfarin on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20295
Chiral
Warfarin on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20271
Chiral
Warfarin on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20193
Chiral
Warfarin on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20161
Warfarin on Lux 5µm Amylose-2 in NP
20080
Chiral
Warfarin on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20076
Warfarin on Lux Amylose-2 with Acetonitrile
19352
Chiral
Warfarin on Lux Cellulose-4 with Acetonitrile
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
19347
Chiral
Warfarin on Lux Cellulose-1 with Formic Acid/Acetonitrile
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19331
Chiral
Warfarin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17418
Chiral
Warfarin on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17312
Chiral
Warfarin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17311