Ambucetamide on Lux 5µm Amylose-1 by SFC

Ambucetamide on Lux 5µm Amylose-1 by SFC
LC Conditions
Column

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

Brand

Lux

Part No

00G-4732-E0

Phase Name

Amylose-1

Elution Type

Isocratic

Mobile Phase

A: CO2/(Isopropanol + 0.5% IPA) 90:10 (v/v)

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

3.00 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Diode Array (PDA) @ (30°C)

Detection Info
Sample Notes

Courtesy of Tanika Van Mulders, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >2

Order Items Used in This Application

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
00G-4732-E0

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

View Product

  • 1. Ambucetamide
  • 2. Ambucetamide
-OEChem-06211003152D<br><br> 49 49  0     1  0  0  0  0  0999 V2000<br>    2.0000    0.5000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -3.5000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.0000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.0000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.5000    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    4.5981    2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    3.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    4.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0622    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -4.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.3500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3860    2.5826    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9875    1.8923    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.0656    0.0251    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.8626    0.0251    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6762    1.9174    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0747    2.6077    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7287    1.4750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.9316    1.4750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2520    4.0826    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8535    3.3923    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7976    0.0251    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5947    0.0251    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.6401    3.4631    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671    4.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0201    4.5369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3722    0.4631    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.5991    1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7522    1.5369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030    2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5560   -3.4631    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -4.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1760   -4.5369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 13  2  0  0  0  0<br>  2 20  1  0  0  0  0<br>  2 21  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  7  1  0  0  0  0<br>  4 13  1  0  0  0  0<br>  4 45  1  0  0  0  0<br>  4 46  1  0  0  0  0<br>  5 10  1  0  0  0  0<br>  5 13  1  0  0  0  0<br>  5 22  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  6 23  1  0  0  0  0<br>  6 24  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 25  1  0  0  0  0<br>  7 26  1  0  0  0  0<br>  8 11  1  0  0  0  0<br>  8 27  1  0  0  0  0<br>  8 28  1  0  0  0  0<br>  9 12  1  0  0  0  0<br>  9 29  1  0  0  0  0<br>  9 30  1  0  0  0  0<br> 10 14  2  0  0  0  0<br> 10 15  1  0  0  0  0<br> 11 16  1  0  0  0  0<br> 11 31  1  0  0  0  0<br> 11 32  1  0  0  0  0<br> 12 17  1  0  0  0  0<br> 12 33  1  0  0  0  0<br> 12 34  1  0  0  0  0<br> 14 18  1  0  0  0  0<br> 14 35  1  0  0  0  0<br> 15 19  2  0  0  0  0<br> 15 36  1  0  0  0  0<br> 16 37  1  0  0  0  0<br> 16 38  1  0  0  0  0<br> 16 39  1  0  0  0  0<br> 17 40  1  0  0  0  0<br> 17 41  1  0  0  0  0<br> 17 42  1  0  0  0  0<br> 18 20  2  0  0  0  0<br> 18 43  1  0  0  0  0<br> 19 20  1  0  0  0  0<br> 19 44  1  0  0  0  0<br> 21 47  1  0  0  0  0<br> 21 48  1  0  0  0  0<br> 21 49  1  0  0  0  0<br>M  END
Compound Name

Ambucetamide

CID

10616

Molecular Formula

C17H28N2O2

Molecular Weight

292

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

1

Similar Applications

Chiral

Ambucetamide on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23335

Chiral

Ambucetamide on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23317

Chiral

Ambucetamide on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23283

Chiral

Ambucetamide on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23281

Chiral

Ambucetamide on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23278

Chiral

Ambucetamide on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21029

Chiral

Ambucetamide on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21028

Chiral

Ambucetamide on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21027

Chiral

Ambucetamide on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21026

Chiral

Ambucetamide on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21025

Chiral

Ambucetamide on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21024

Chiral

Ambucetamide on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21023

Chiral

Ambucetamide on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21022

Chiral

Ambucetamide on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21021

Ambucetamide on Lux 5µm Amylose-2 by SFC

21020

Ambucetamide on Lux 5µm Amylose-2 by SFC

21019

Ambucetamide on Lux 5µm Amylose-2 by SFC

21018

Ambucetamide on Lux 5µm Amylose-2 by SFC

21017

Chiral

Ambucetamide Lux 5µ Cellulose-2 in RP 80% MeOH

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

18571

Ambucetamide on Lux 5µm Amylose-2 in RP 60% CH3CN

18545

Chiral

Ambucetamide on Lux 5 µm Cellulose-1 250 x 4.6mm in RP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

18544

Chiral

Ambucetamide on Lux 5µ Cellulose-2 in NP 60%IPA

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17853

Chiral

Ambucetamide on Lux 5µ Cellulose-2 in NP 40%IPA

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17852

Chiral

Ambucetamide on Lux 5µ Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17849

Chiral

Ambucetamide on Lux Cellulose-2

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17413

Chiral

Ambucetamide on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17412