Flurbiprofen on Lux 5µm Amylose-1 by SFC

Flurbiprofen on Lux 5µm Amylose-1 by SFC
LC Conditions
Column

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

Brand

Lux

Part No

00G-4732-E0

Phase Name

Amylose-1

Elution Type

Isocratic

Mobile Phase

A: CO2/(Methanol + 0.5% IPA) 90:10 (v/v)

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

3.00 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Diode Array (PDA) @ (30°C)

Detection Info
Sample Notes

Courtesy of Tanika Van Mulders, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >2

Order Items Used in This Application

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
00G-4732-E0

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

View Product

  • 1. Flurbiprofen
  • 2. Flurbiprofen
-OEChem-06211003152D<br><br> 31 32  0     1  0  0  0  0  0999 V2000<br>    2.0000    0.9050    0.0000 F   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -3.5950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -2.0950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.0950    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -2.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    3.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    3.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.9450    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -0.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -0.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    0.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5560   -2.0581    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1760   -3.1319    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    2.0950    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    2.0950    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    3.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    3.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    4.5250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -3.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  2 13  1  0  0  0  0<br>  2 31  1  0  0  0  0<br>  3 13  2  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4 11  1  0  0  0  0<br>  4 13  1  0  0  0  0<br>  4 19  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  6  9  2  0  0  0  0<br>  6 10  1  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 20  1  0  0  0  0<br>  8 10  2  0  0  0  0<br>  8 21  1  0  0  0  0<br> 10 22  1  0  0  0  0<br> 11 23  1  0  0  0  0<br> 11 24  1  0  0  0  0<br> 11 25  1  0  0  0  0<br> 12 14  2  0  0  0  0<br> 12 15  1  0  0  0  0<br> 14 16  1  0  0  0  0<br> 14 26  1  0  0  0  0<br> 15 17  2  0  0  0  0<br> 15 27  1  0  0  0  0<br> 16 18  2  0  0  0  0<br> 16 28  1  0  0  0  0<br> 17 18  1  0  0  0  0<br> 17 29  1  0  0  0  0<br> 18 30  1  0  0  0  0<br>M  END
Compound Name

Flurbiprofen

CID

3394

Molecular Formula

C15H13FO2

Molecular Weight

244

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Six Standard (RS) on Kinetex C18, 2.6 µm 150x3mm

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 3 mm, Ea

28579

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Standard (RS) on Kinetex C18, 2.6 µm 150x3mm

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 3 mm, Ea

28578

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ SST on Kinetex C18, 2.6 µm 150x3mm

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 3 mm, Ea

28577

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Sensitivity on Kinetex C18, 2.6 µm 150x3mm

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 3 mm, Ea

28576

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Five Standard on Kinetex C18, 2.6 µm 150x3 mm

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 3 mm, Ea

28575

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_Standard solution on Kinetex C18, 2.6 µm 150x3 mm

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 3 mm, Ea

28574

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Six Standard (RS) on Kinetex C18, 5 µm 250x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28573

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Standard (RS) on Kinetex C18, 5 µm 250x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28572

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ SST on Kinetex C18, 5 µm 250x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28571

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Sensitivity on Kinetex C18, 5 µm 250x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28570

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Five Standard on Kinetex C18, 5 µm 250x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28569

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_Standard solution on Kinetex C18, 5 µm 250x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28568

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Six Standard (RS) on Luna Omega C18, 5 µm 250x4.6mm

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28556

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Standard (RS) on Luna Omega C18, 5 µm 250x4.6mm

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28555

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ SST on Luna Omega C18, 5 µm 250x4.6mm

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28554

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Sensitivity on Luna Omega C18, 5 µm 250x4.6mm

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28553

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_ Five Standard on Luna Omega C18, 5 µm 250x4.6mm

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28552

Reversed Phase

Verification of proposed USP-NF Flurbiprofen sodium Assay and Organic Impurities Monograph and subsequent Modernization under Allowable Adjustments_Standard solution on Luna Omega C18, 5 µm 250x4.6mm

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

28551

Chiral

Lux i-Amylose-3 Separation for Flurbiprofen

Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea

25352

Chiral

Lux i-Amylose-3 Separation for Flurbiprofen

Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea

25346

Chiral

Flurbiprofen on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23298

Chiral

Flurbiprofen on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23285

Chiral

Flurbiprofen on LUX Amylose-1 5u in RP

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23206

Flurbiprofen on Lux 5µm Amylose-2 by SFC

21139

Flurbiprofen on Lux 5µm Amylose-2 by SFC

21138

Flurbiprofen on Lux 5µm Amylose-2 by SFC

21137

Flurbiprofen on Lux 5µm Amylose-2 by SFC

21136

Flurbiprofen on Lux 5µm Amylose-2 by SFC

21135

Flurbiprofen on Lux 5µm Amylose-2 by SFC

21134

Chiral

Flurbiprofen on Lux Cellulose-3 with Acetonitrile

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

19356

Flurbiprofen on Lux Amylose-2 with Acetonitrile

19353

Effect of Acidic Additives on the RP Enantioseparation of Flurbiprofen on Lux Amylose-2

19327

NSAIDs on Onyx C18 (Luna Comparison)

15649

Reversed Phase

Fluoropharmaceuticals using Synergi Fusion-RP

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14846

Reversed Phase

Nonsteroidal Anti-inflammatory

Luna 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

1179