Oxprenolol on Lux 5µm Amylose-1 by SFC
LC Conditions
Column
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
Brand
Lux
Part No
00G-4732-E0
Phase Name
Amylose-1
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.5% IPA) 80:20 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Tanika Van Mulders, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >2
Order Items Used in This Application
- 1. Oxprenolol
- 2. Oxprenolol
-OEChem-06211003152D<br><br> 42 42 0 1 0 0 0 0 0999 V2000<br> 6.3301 -0.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 2.2500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.7500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 8.9282 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.2742 0.6674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6728 1.3577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6592 0.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 2.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5252 2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4082 -0.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8067 -0.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5482 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3082 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4842 1.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3312 1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.1042 2.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 -3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3335 -2.7250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1306 -2.7250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 1 0 0 0 0<br> 1 11 1 0 0 0 0<br> 2 6 1 0 0 0 0<br> 2 33 1 0 0 0 0<br> 3 12 1 0 0 0 0<br> 3 17 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 24 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 20 1 0 0 0 0<br> 5 21 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 22 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 8 26 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 10 32 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 12 14 2 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 16 2 0 0 0 0<br> 15 36 1 0 0 0 0<br> 16 37 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 38 1 0 0 0 0<br> 17 39 1 0 0 0 0<br> 18 19 2 0 0 0 0<br> 18 40 1 0 0 0 0<br> 19 41 1 0 0 0 0<br> 19 42 1 0 0 0 0<br>M END
Compound Name
Oxprenolol
CID
4631
Molecular Formula
C15H23NO3
Molecular Weight
265
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Oxprenolol on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23295
Chiral
Oxprenolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21297
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21296
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21295
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21294
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21293
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21292
Oxprenolol on Lux 5µm Amylose-2 by SFC
21291
Oxprenolol on Lux 5µm Amylose-2 by SFC
21290
Oxprenolol on Lux 5µm Amylose-2 in NP
20553
Chiral
Oxprenolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20544
Chiral
Oxprenolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20079
Chiral
RP Enantioseparation of Oxprenolol on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19449
Chiral
Oxprenolol on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17664
Chiral
Oxprenolol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17482
Chiral
Oxprenolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17481