Warfarin on Lux 5µm Amylose-1 by SFC
LC Conditions
Column
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
Brand
Lux
Part No
00G-4732-E0
Phase Name
Amylose-1
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.25% IPA + 0.25% TFA) 90:10 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Tanika Van Mulders, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >2
Order Items Used in This Application
- 1. Warfarin
- 2. Warfarin
-OEChem-06211003152D<br><br> 39 41 0 1 0 0 0 0 0999 V2000<br> 6.3301 1.9400 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.9400 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.0600 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0600 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.0600 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0901 -0.0947 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.9400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0901 1.9747 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.4400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9962 0.4192 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9962 1.4608 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -1.6426 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -0.9523 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.6800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 1.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0829 -0.7146 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1120 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.1800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3520 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0829 2.5946 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 1.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5319 0.1071 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5319 1.7729 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 10 1 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 10 1 0 0 0 0<br> 2 39 1 0 0 0 0<br> 3 9 2 0 0 0 0<br> 4 12 2 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 10 2 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 25 1 0 0 0 0<br> 7 26 1 0 0 0 0<br> 8 13 2 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 11 15 1 0 0 0 0<br> 11 16 2 0 0 0 0<br> 12 19 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 27 1 0 0 0 0<br> 14 18 2 0 0 0 0<br> 14 28 1 0 0 0 0<br> 15 20 2 0 0 0 0<br> 16 22 1 0 0 0 0<br> 16 29 1 0 0 0 0<br> 17 21 2 0 0 0 0<br> 17 30 1 0 0 0 0<br> 18 21 1 0 0 0 0<br> 18 31 1 0 0 0 0<br> 19 32 1 0 0 0 0<br> 19 33 1 0 0 0 0<br> 19 34 1 0 0 0 0<br> 20 23 1 0 0 0 0<br> 20 35 1 0 0 0 0<br> 21 36 1 0 0 0 0<br> 22 23 2 0 0 0 0<br> 22 37 1 0 0 0 0<br> 23 38 1 0 0 0 0<br>M END
Compound Name
Warfarin
CID
6691
Molecular Formula
C19H16O4
Molecular Weight
308
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
1
Similar Applications
Chiralpak-IG Separation for Warfarin
25364
Chiral
Warfarin on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23308
Chiral
Warfarin on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23303
Chiral
Warfarin on LUX 5u Amylose-1 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23165
Reversed Phase
Pharmaceutical Mix on Kinetex 1.7 F5 50x2.1mm
Kinetex 1.7 µm F5 100 Å, LC Column 50 x 2.1 mm, Ea
22813
Chiral
Normal Phase Loading Study for Warfarin on Lux 5um Cellulose-1 150x4.6
Lux 5 µm Cellulose-1, LC Column 150 x 4.6 mm, Ea
21922
Chiral
Normal Phase Loading Study for Warfarin on Lux 5um Cellulose-1 150x21.2 - AXIA
Lux 5 µm Cellulose-1, LC Column 150 x 21.2 mm, AXIA Packed, Ea
21921
Chiral
SFC Loading Study for Warfarin on Lux 5um Cellulose-1 150x21.2 - AXIA
Lux 5 µm Cellulose-1, LC Column 150 x 21.2 mm, AXIA Packed, Ea
21918
Chiral
SFC Loading Study for Warfarin on Lux 5um Cellulose-1 150x4.6
Lux 5 µm Cellulose-1, LC Column 150 x 4.6 mm, Ea
21917
Chiral
Warfarin on Lux 5 um Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21865
Chiral
Warfarin on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21422
Chiral
Warfarin on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21421
Chiral
Warfarin on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21420
Warfarin on Lux 5µm Amylose-2 in NP
20508
Chiral
Warfarin on Lux 5µm Cellulose-3 in PO
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20360
Chiral
Warfarin on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20295
Chiral
Warfarin on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20271
Chiral
Warfarin on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20193
Chiral
Warfarin on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20161
Warfarin on Lux 5µm Amylose-2 in NP
20080
Chiral
Warfarin on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20076
Warfarin on Lux Amylose-2 with Acetonitrile
19352
Chiral
Warfarin on Lux Cellulose-4 with Acetonitrile
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
19347
Chiral
Warfarin on Lux Cellulose-1 with Formic Acid/Acetonitrile
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19331
Chiral
Warfarin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17418
Chiral
Warfarin on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17312
Chiral
Warfarin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17311