Zopiclone on Lux 5µm i-Cellulose-5 250x4.6mm (MS)
LC Conditions
Column
Lux 5 µm i-Cellulose-5, LC Column 250 x 4.6 mm, EA
Brand
Lux
Part No
00G-4756-E0
Phase Name
i-Cellulose-5
Elution Type
Isocratic
Mobile Phase
A: 5mM Ammonium Bicarbonate
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
20
80
Flow Rate
1.00 mL/min
Temperature
20°C
Detection
Mass Spectrometer (MS) @ (20°C)
Detection Info
Order Items Used in This Application
- 1. Zopiclone
- 2. Zopiclone
-OEChem-06211003152D<br><br> 44 47 0 1 0 0 0 0 0999 V2000<br> 9.2619 -2.2732 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9889 -0.5179 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3426 0.0201 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9889 -4.0284 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6318 1.1769 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2531 3.0779 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2619 -2.2732 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.2732 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -3.2732 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7619 -1.4072 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9639 1.9212 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6103 1.3831 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2746 2.8717 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9209 2.3336 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6783 -1.4685 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.3211 0.2264 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5637 4.0284 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.7732 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.7732 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6783 -3.0779 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2619 -2.2732 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7619 -3.1392 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.7732 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.7732 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7619 -3.1392 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7619 -1.4072 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.2619 -2.2732 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4170 2.2132 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5814 1.4333 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6308 0.7634 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2241 1.2958 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2540 3.4914 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6608 2.9590 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4678 2.0416 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3035 2.8215 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0785 -0.8661 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1531 3.8358 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7564 4.6178 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9744 4.2211 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4519 -3.6762 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.4632 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -3.0832 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0719 -3.6762 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0719 -0.8702 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 27 1 0 0 0 0<br> 2 15 1 0 0 0 0<br> 2 16 1 0 0 0 0<br> 3 16 2 0 0 0 0<br> 4 20 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 12 1 0 0 0 0<br> 5 16 1 0 0 0 0<br> 6 13 1 0 0 0 0<br> 6 14 1 0 0 0 0<br> 6 17 1 0 0 0 0<br> 7 15 1 0 0 0 0<br> 7 20 1 0 0 0 0<br> 7 21 1 0 0 0 0<br> 8 18 2 0 0 0 0<br> 8 23 1 0 0 0 0<br> 9 19 2 0 0 0 0<br> 9 24 1 0 0 0 0<br> 10 21 2 0 0 0 0<br> 10 26 1 0 0 0 0<br> 11 13 1 0 0 0 0<br> 11 28 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 12 14 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 13 32 1 0 0 0 0<br> 13 33 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 17 37 1 0 0 0 0<br> 17 38 1 0 0 0 0<br> 17 39 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 21 22 1 0 0 0 0<br> 22 25 2 0 0 0 0<br> 22 40 1 0 0 0 0<br> 23 24 2 0 0 0 0<br> 23 41 1 0 0 0 0<br> 24 42 1 0 0 0 0<br> 25 27 1 0 0 0 0<br> 25 43 1 0 0 0 0<br> 26 27 2 0 0 0 0<br> 26 44 1 0 0 0 0<br>M END
Compound Name
Zopiclone
CID
5735
Molecular Formula
C17H17ClN6O3
Molecular Weight
388
No. Hydrogen Bond Acceptors
7
Similar Applications
Reversed Phase
Pain Panel/Drug Screening by LCMS using Kinetex 2.6u C18 50x3.0mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea
20689
Chiral
Zopiclone on Lux 5µm Cellulose-4 in PO
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20377
Chiral
Zopiclone on Lux 5µm Cellulose-2 in PO
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20374
Chiral
Zopiclone on Lux 5µm Cellulose-3 in PO
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20361
Chiral
Zopiclone on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20301
Chiral
Zopiclone on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20242
Reversed Phase
Benzodiazepines in Human Plasma or Urine- Kinetex 1.7 µm XB-C18 100 x 2.1 mm
Kinetex 1.7 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19766
Reversed Phase
Benzodiazepines in Human Plasma or Urine- Kinetex 2.6 µm XB-C18 100 x 2.1 mm
Kinetex 2.6 µm XB-C18 100 Å, LC Column 100 x 2.1 mm, Ea
19765
Reversed Phase
Toxicological Screen for benzodiazepines- Kinetex 2.6 µm C18 100 x 2.1 mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19764
Reversed Phase
Toxicological Screen for benzodiazepines- Kinetex 2.6 µm XB-C18 100 x 2.1 mm
Kinetex 2.6 µm XB-C18 100 Å, LC Column 100 x 2.1 mm, Ea
19763
Chiral
Effect of Buffer on RP Enantioseparation of Zopiclone on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19374
Chiral
Zopiclone on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17430