Zopiclone on Lux 5µm i-Cellulose-5 250x4.6mm (MS)

Zopiclone on Lux 5µm i-Cellulose-5 250x4.6mm (MS)
LC Conditions
Column

Lux 5 µm i-Cellulose-5, LC Column 250 x 4.6 mm, EA

Brand

Lux

Part No

00G-4756-E0

Phase Name

i-Cellulose-5

Elution Type

Isocratic

Mobile Phase

A: 5mM Ammonium Bicarbonate

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

20

80

Flow Rate

1.00 mL/min

Temperature

20°C

Detection

Mass Spectrometer (MS) @ (20°C)

Detection Info

Order Items Used in This Application

Lux 5 µm i-Cellulose-5, LC Column 250 x 4.6 mm, EA
00G-4756-E0

Lux 5 µm i-Cellulose-5, LC Column 250 x 4.6 mm, EA

View Product

  • 1. Zopiclone
  • 2. Zopiclone
-OEChem-06211003152D<br><br> 44 47  0     1  0  0  0  0  0999 V2000<br>    9.2619   -2.2732    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9889   -0.5179    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3426    0.0201    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9889   -4.0284    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6318    1.1769    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2531    3.0779    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2619   -2.2732    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.2732    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -3.2732    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7619   -1.4072    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9639    1.9212    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6103    1.3831    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2746    2.8717    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.9209    2.3336    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6783   -1.4685    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    4.3211    0.2264    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5637    4.0284    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.7732    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.7732    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6783   -3.0779    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2619   -2.2732    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7619   -3.1392    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.7732    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.7732    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7619   -3.1392    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7619   -1.4072    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.2619   -2.2732    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4170    2.2132    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5814    1.4333    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6308    0.7634    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2241    1.2958    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2540    3.4914    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6608    2.9590    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.4678    2.0416    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3035    2.8215    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0785   -0.8661    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1531    3.8358    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7564    4.6178    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9744    4.2211    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.4519   -3.6762    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.4632    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -3.0832    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0719   -3.6762    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0719   -0.8702    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 27  1  0  0  0  0<br>  2 15  1  0  0  0  0<br>  2 16  1  0  0  0  0<br>  3 16  2  0  0  0  0<br>  4 20  2  0  0  0  0<br>  5 11  1  0  0  0  0<br>  5 12  1  0  0  0  0<br>  5 16  1  0  0  0  0<br>  6 13  1  0  0  0  0<br>  6 14  1  0  0  0  0<br>  6 17  1  0  0  0  0<br>  7 15  1  0  0  0  0<br>  7 20  1  0  0  0  0<br>  7 21  1  0  0  0  0<br>  8 18  2  0  0  0  0<br>  8 23  1  0  0  0  0<br>  9 19  2  0  0  0  0<br>  9 24  1  0  0  0  0<br> 10 21  2  0  0  0  0<br> 10 26  1  0  0  0  0<br> 11 13  1  0  0  0  0<br> 11 28  1  0  0  0  0<br> 11 29  1  0  0  0  0<br> 12 14  1  0  0  0  0<br> 12 30  1  0  0  0  0<br> 12 31  1  0  0  0  0<br> 13 32  1  0  0  0  0<br> 13 33  1  0  0  0  0<br> 14 34  1  0  0  0  0<br> 14 35  1  0  0  0  0<br> 15 18  1  0  0  0  0<br> 15 36  1  0  0  0  0<br> 17 37  1  0  0  0  0<br> 17 38  1  0  0  0  0<br> 17 39  1  0  0  0  0<br> 18 19  1  0  0  0  0<br> 19 20  1  0  0  0  0<br> 21 22  1  0  0  0  0<br> 22 25  2  0  0  0  0<br> 22 40  1  0  0  0  0<br> 23 24  2  0  0  0  0<br> 23 41  1  0  0  0  0<br> 24 42  1  0  0  0  0<br> 25 27  1  0  0  0  0<br> 25 43  1  0  0  0  0<br> 26 27  2  0  0  0  0<br> 26 44  1  0  0  0  0<br>M  END
Compound Name

Zopiclone

CID

5735

Molecular Formula

C17H17ClN6O3

Molecular Weight

388

No. Hydrogen Bond Acceptors

7

Similar Applications

Reversed Phase

Pain Panel/Drug Screening by LCMS using Kinetex 2.6u C18 50x3.0mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea

20689

Chiral

Zopiclone on Lux 5µm Cellulose-4 in PO

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20377

Chiral

Zopiclone on Lux 5µm Cellulose-2 in PO

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20374

Chiral

Zopiclone on Lux 5µm Cellulose-3 in PO

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20361

Chiral

Zopiclone on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20301

Chiral

Zopiclone on Lux 5µm Cellulose-1 in RP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20242

Reversed Phase

Benzodiazepines in Human Plasma or Urine- Kinetex 1.7 µm XB-C18 100 x 2.1 mm

Kinetex 1.7 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19766

Reversed Phase

Benzodiazepines in Human Plasma or Urine- Kinetex 2.6 µm XB-C18 100 x 2.1 mm

Kinetex 2.6 µm XB-C18 100 Å, LC Column 100 x 2.1 mm, Ea

19765

Reversed Phase

Toxicological Screen for benzodiazepines- Kinetex 2.6 µm C18 100 x 2.1 mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19764

Reversed Phase

Toxicological Screen for benzodiazepines- Kinetex 2.6 µm XB-C18 100 x 2.1 mm

Kinetex 2.6 µm XB-C18 100 Å, LC Column 100 x 2.1 mm, Ea

19763

Chiral

Effect of Buffer on RP Enantioseparation of Zopiclone on Lux Cellulose-1

Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea

19374

Chiral

Zopiclone on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17430