Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 Stability (After aggressive solvent exposure)
LC Conditions
Column
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4762-E0
Phase Name
i-Amylose-1
Elution Type
Isocratic
Mobile Phase
A: 0.1% DEA in Hexane
B: 0.1% DEA in IPA
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
90
10
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Mianserin
- 2. Mianserin
-OEChem-06211003152D<br><br> 40 43 0 1 0 0 0 0 0999 V2000<br> 4.5438 -0.7951 0.0000 N 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.8430 -1.9740 0.0000 N 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.6428 -0.3612 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.7732 -0.9347 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6376 -1.8325 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4203 0.6137 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7815 -2.4259 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4447 -0.3612 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0438 1.3955 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0438 1.3955 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6673 0.6137 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0146 -2.5341 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3880 0.7530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1973 -1.0814 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6782 2.3709 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6578 0.9360 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.7197 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6494 2.5341 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1950 -0.7821 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4268 0.2334 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0674 -0.1303 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5255 -0.3663 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.1708 -1.0815 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8984 -2.3950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2364 -1.6718 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4209 -2.9302 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2167 -2.8675 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6024 1.6645 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9058 2.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6674 -2.0205 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.5010 -2.8814 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3619 -3.0477 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0071 0.2639 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0524 -1.6842 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0704 2.8511 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7887 1.5420 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3866 1.8098 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4252 3.1121 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6478 -1.2055 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0185 0.4185 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 3 1 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 8 1 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 7 1 0 0 0 0<br> 2 12 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 4 22 1 0 0 0 0<br> 4 23 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 5 25 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 13 2 0 0 0 0<br> 7 26 1 0 0 0 0<br> 7 27 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 8 14 2 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 15 2 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 10 29 1 0 0 0 0<br> 11 16 2 0 0 0 0<br> 12 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 33 1 0 0 0 0<br> 14 19 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 35 1 0 0 0 0<br> 16 20 1 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 18 2 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 19 20 2 0 0 0 0<br> 19 39 1 0 0 0 0<br> 20 40 1 0 0 0 0<br>M END
Compound Name
Mianserin
CID
4184
Molecular Formula
C18H20N2
Molecular Weight
264
No. Hydrogen Bond Acceptors
2
Similar Applications
Chiral
Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 in NP
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24295
Chiral
Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 Stability (After aggressive solvent exposure)
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24281
Chiral
Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 Stability (Before aggressive solvent exposure)
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24280
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23338
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23332
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23323
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23315
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23300
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23294
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23289
Chiral
Mianserin on LUX Amylose-1 5u in RP
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23200
Chiral
Mianserin on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23196
Chiral
Mianserin on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23194
Chiral
Mianserine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21235
Chiral
Mianserine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21234
Chiral
Mianserine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21233
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21232
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21231
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21230
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21229
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21228
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21227
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21226
Chiral
Mianserine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21225
Chiral
Mianserine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21224
Chiral
Mianserine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21223
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21222
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21221
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21220
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21219
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21218
Chiral
Mianserin on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20225
Chiral
RP Enantioseparation of Mianserin on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19382
Chiral
Mianserin on Lux 5µm Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17477
Chiral
Mianserin on Lux 3µm Cellulose-1
Lux 3 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17471
Chiral
Mianserin on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17433
Chiral
Mianserin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17432