Chiral Separation of Lorazepam on Lux 5µm i-Amylose-1 250 x 4.6mm in NP
LC Conditions
Column
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4762-E0
Phase Name
i-Amylose-1
Elution Type
Isocratic
Mobile Phase
A: n-Hexane
B: Acetone
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
60
40
Flow Rate
1.00 mL/min
Temperature
25°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Lorazepam
- 2. Lorazepam
-OEChem-06211003152D<br><br> 31 33 0 1 0 0 0 0 0999 V2000<br> 8.1647 -0.1360 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6300 0.5528 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -1.1602 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1204 -2.8430 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 -2.2836 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7439 -0.2592 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -0.6602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 -0.0367 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -1.6602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9413 0.9383 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3100 -1.1602 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3946 -0.1255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7439 -2.0611 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3946 -2.1948 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -0.6393 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -1.6810 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8969 1.2330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2083 1.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1194 2.2079 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4308 2.5934 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3864 2.8881 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9801 -0.6352 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8568 -2.8881 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 0.4945 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 -2.8148 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8364 -1.9930 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6158 1.4357 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7119 2.3907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9763 3.0151 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5243 3.4926 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.6232 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 17 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 3 31 1 0 0 0 0<br> 4 13 2 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 13 1 0 0 0 0<br> 5 23 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 11 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 9 2 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 9 14 1 0 0 0 0<br> 10 17 1 0 0 0 0<br> 10 18 2 0 0 0 0<br> 11 13 1 0 0 0 0<br> 11 22 1 0 0 0 0<br> 12 15 2 0 0 0 0<br> 12 24 1 0 0 0 0<br> 14 16 2 0 0 0 0<br> 14 25 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 16 26 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 18 20 1 0 0 0 0<br> 18 27 1 0 0 0 0<br> 19 21 1 0 0 0 0<br> 19 28 1 0 0 0 0<br> 20 21 2 0 0 0 0<br> 20 29 1 0 0 0 0<br> 21 30 1 0 0 0 0<br>M END
Compound Name
Lorazepam
CID
3958
Molecular Formula
C15H10Cl2N2O2
Molecular Weight
321
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Chiral Separation of Lorazepam on Lux 5µm i-Amylose-1 250 x 4.6mm in NP
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24453
Reversed Phase
7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea
23560
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
23445
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23444
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22122
Reversed Phase
Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22121
Reversed Phase
Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22120
Reversed Phase
Pain Panel Benzodiazapines using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22109
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22104
Chiral
RP Enantioseparation of Lorazepam on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19441
Chiral
Effect of Temperature and Additive on Enantioseparation of Lorazepam on Lux Cellulose-2
Lux 3 µm Cellulose-2, LC Column 150 x 2 mm, Ea
19368