Chiral Separation of Aminoglutethimide on Lux 5µm i-Amylose-1 in NP
LC Conditions
Column
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4762-E0
Phase Name
i-Amylose-1
Elution Type
Isocratic
Mobile Phase
A: Ethyl Acetate
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Aminoglutethimide
- 2. Aminoglutethimide
-OEChem-06211003142D<br><br> 33 34 0 1 0 0 0 0 0999 V2000<br> 2.0000 -0.5005 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.5005 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.0005 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7320 2.9636 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5005 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0005 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2320 0.3655 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2320 0.3655 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.0005 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0005 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.5005 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2320 0.3655 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.2315 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2320 0.3655 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2320 2.0976 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7320 1.2315 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2320 2.0976 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -1.1082 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -0.4179 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8147 0.5776 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1244 0.9761 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -2.5831 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -1.8929 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.3105 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2320 0.9855 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6120 0.3655 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2320 -0.2545 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1120 1.2315 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5420 -0.1714 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9220 2.6345 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3520 1.2315 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3520 2.9636 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4220 3.5005 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 10 2 0 0 0 0<br> 2 11 2 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 3 24 1 0 0 0 0<br> 4 17 1 0 0 0 0<br> 4 32 1 0 0 0 0<br> 4 33 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 18 1 0 0 0 0<br> 6 19 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 20 1 0 0 0 0<br> 7 21 1 0 0 0 0<br> 8 13 2 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 9 22 1 0 0 0 0<br> 9 23 1 0 0 0 0<br> 12 25 1 0 0 0 0<br> 12 26 1 0 0 0 0<br> 12 27 1 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 28 1 0 0 0 0<br> 14 16 2 0 0 0 0<br> 14 29 1 0 0 0 0<br> 15 17 2 0 0 0 0<br> 15 30 1 0 0 0 0<br> 16 17 1 0 0 0 0<br> 16 31 1 0 0 0 0<br>M END
Compound Name
Aminoglutethimide
CID
2145
Molecular Formula
C13H16N2O2
Molecular Weight
232
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Chiral Separation of Aminoglutethimide on Lux 5µm i-Amylose-1 in NP
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24497
Chiral
Aminoglutethimide on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20206
Chiral
Aminoglutethimide on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20205
Chiral
Aminoglutethimide on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20169
Chiral
Aminoglutethimide on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20107
Chiral
Aminoglutethimide on Lux 5µm Cellulose-1 in PO
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20069
Chiral
Aminoglutethimide on Lux 5µm Cellulose-2 in PO
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20066
Chiral
RP Enantioseparation of Aminoglutethimide on Lux Cellulose-2
Lux 3 µm Cellulose-2, LC Column 150 x 2 mm, Ea
19398
Chiral
Effect of Buffer on RP Enantioseparation of Aminoglutethimide on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19369
Chiral
Aminoglutethimide on Lux 5µ Cellulose-2 in NP (IPA)
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17851
Chiral
Aminoglutethimide on Lux 5µ Cellulose-2 250 x 4.6mm in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17682
Chiral
Aminoglutethimide on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17667
Chiral
Aminoglutethimide on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17442
Chiral
Aminoglutethimide on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17441
Chiral
Aminoglutethimide on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17391