Click here to download
LC Conditions
Column

bioZen 1.6 µm Peptide PS-C18, LC Column 150 x 2.1 mm, Ea

Brand

Biozen LC

Part No

00F-4770-AN

Phase Name

Peptide PS-C18

Elution Type

Gradient

Mobile Phase

A: 0.1% Formic acid in water

B: 0.1% Formic acid in acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

99

1

2

0.5

99

1

3

50

50

50

4

55

50

50

5

56

5

95