Lux i-Amylose-3 Separation for Carprofen
LC Conditions
Column
Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4779-E0
Phase Name
i-Amylose-3
Elution Type
Isocratic
Mobile Phase
A: Methanol
B: Formic Acid
Gradient Profile
Step No.
Time(min)
%A
%B
1
6
100
0.1
Flow Rate
1.00 mL/min
Temperature
25°C
System
Agilent Technologies Agilent Technologies 1100 Series
Detection
LC/UV (DAD, PDA) @ 254 nm (nanometers)
Detection Info
Sample Notes
2 mg/mL in Ethanol
Order Items Used in This Application
- 1. Carprofen
- 2. Carprofen
-OEChem-06211003142D<br><br> 31 33 0 1 0 0 0 0 0999 V2000<br> 2.0000 -1.7403 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.0258 -0.3211 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7431 -1.4850 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8717 1.1203 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3717 -0.4185 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6808 0.5325 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3717 -0.4185 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3991 -0.0039 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0627 0.5325 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3764 0.2078 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.6962 0.7648 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0567 -1.2033 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0772 -0.9946 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6868 -1.2033 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0473 0.7648 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6818 1.1600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6663 -0.9946 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0484 -0.5328 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3444 -0.0039 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9598 0.6669 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8809 1.3566 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8717 1.7403 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8583 -1.7907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4903 -1.4569 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8852 -1.7907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8626 1.3566 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.2722 0.9707 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8711 1.7504 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0914 1.3493 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7384 0.1273 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.4424 -0.7803 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 17 1 0 0 0 0<br> 2 18 1 0 0 0 0<br> 2 31 1 0 0 0 0<br> 3 18 2 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 22 1 0 0 0 0<br> 5 6 2 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 12 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 7 9 2 0 0 0 0<br> 7 14 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 11 2 0 0 0 0<br> 8 13 1 0 0 0 0<br> 9 15 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 10 18 1 0 0 0 0<br> 10 20 1 0 0 0 0<br> 11 21 1 0 0 0 0<br> 12 13 2 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 17 2 0 0 0 0<br> 14 25 1 0 0 0 0<br> 15 19 2 0 0 0 0<br> 15 26 1 0 0 0 0<br> 16 27 1 0 0 0 0<br> 16 28 1 0 0 0 0<br> 16 29 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 19 30 1 0 0 0 0<br>M END
Compound Name
Carprofen
CID
2581
Molecular Formula
C15H12ClNO2
Molecular Weight
273
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Lux 3µ i-Amylose-3 Separation for Carprofen
Lux 3 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea
25385
Chiral
Lux i-Amylose-3 Separation for Carprofen
Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea
25351
Chiral
Carprofen on Lux 5 µm Amylose-1 in RP
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23234
Chiral
Carprofen on LUX Amylose-1 5u in RP
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23204
Chiral
Carprofen on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20478
Chiral
Carprofen on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20406
Chiral
Carprofen on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20385
Chiral
Carprofen on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20314
Chiral
Carprofen on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20278
Chiral
Carprofen on Lux Cellulose-1 with Formic Acid/Acetonitrile
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19335