USP Tigecycline Assay System Suitability Solution on Luna Omega 5u C18 150x4.6mm using Agilent 1260 Quaternary UHPLC system

USP Tigecycline Assay System Suitability Solution on Luna Omega 5u C18 150x4.6mm using Agilent 1260 Quaternary UHPLC system
LC Conditions
Column

Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna Omega

Part No

00F-4785-E0

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile:Buffer (140:860) Buffer: 4.35g/L of dibasic Potassium Phosphate and 0.93 g/L of EDTA, adjusted with Phosphoric acid to a pH of 6.2

Pre-mixed

Gradient Profile

Step No.

Time(min)

%A

%B

1

45

100

Flow Rate

1.00 mL/min

Temperature

30°C

System

Agilent Technologies 1260 Infinity Agilent Technologies 1200 Series Quaternary LC System

Detection

UV-Vis Abs.-Diode Array (PDA) @ 248 nm (nanometers)

Detection Info

Order Items Used in This Application

Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4785-E0

Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Tigecycline Epimer
  • 2. Tigecycline
Similar Applications

No Similar applications found.