Amino Sugars

Amino Sugars
LC Conditions
Column

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

Brand

Rezex

Part No

00H-0138-K0

Phase Name

ROA-Organic Acid H+ (8%)

Elution Type

Isocratic

Mobile Phase

A: 1% Phosphoric acid

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

0.60 mL/min

Temperature

22°C

Detection

Refractive Index (RI) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Carbo-H 4 x 3.0mm, 10/Pk Part No.: AJ0-4490 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
00H-0138-K0

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

View Product

  • 1. Glucose
  • 2. N-Acetylglucoseamine
  • 3. N-Acetylgalactosamine
-OEChem-06211003162D<br><br> 24 23  0     1  0  0  0  0  0999 V2000<br>    5.4641    1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0622   -0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    6.3301   -0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.7320    0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    7.1962    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2002    0.6750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3342   -0.6750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0662   -0.6750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4682    0.6750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5947    0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7976    0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0611   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.5991    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  7  1  0  0  0  0<br>  1 19  1  0  0  0  0<br>  2  8  1  0  0  0  0<br>  2 20  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  3 22  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 23  1  0  0  0  0<br>  5 11  1  0  0  0  0<br>  5 24  1  0  0  0  0<br>  6 12  2  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 11  1  0  0  0  0<br>  9 15  1  0  0  0  0<br> 10 12  1  0  0  0  0<br> 10 16  1  0  0  0  0<br> 11 17  1  0  0  0  0<br> 11 18  1  0  0  0  0<br> 12 21  1  0  0  0  0<br>M  END
Compound Name

Glucose

CID

24749

Molecular Formula

C6H12O6

Molecular Weight

180

No. Hydrogen Bond Acceptors

6

No. Hydrogen Bond Donors

5

Similar Applications

Hydrophilic Interaction

15 Sugars Analyzed by LC-RI using Luna Omega SUGAR

Luna Omega 3 µm SUGAR 100 Å, LC Column 150 x 4.6 mm, Ea

25453

Normal Phase

Complex Sugars on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

17010

Ion Exclusion

Beer Well Drop on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16647

Ion Exclusion

25 Hr on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16646

Ion Exclusion

10 Hr on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16645

Ion Exclusion

6 Hr on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16644

Ion Exclusion

Yeast Prop. on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16643

Application Specific

TMS Sugars on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16248

Ion Exclusion

Sialic acid mix using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

15769

Ion Exclusion

Saccharide analysis using Rezex RHM

Rezex RHM-Monosaccharide H+ (8%), LC Column 300 x 7.8 mm, Ea

14991

Ion Exclusion

Fermentation yeast sample using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14990

Ion Exclusion

Fermentation sample #3 using Rexex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14989

Ion Exclusion

Fermentation sample #2 using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14988

Ion Exclusion

Fermentation sample #1 using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14987

Ion Exclusion

Saccharide analysis using Rezex RPM

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

14985

Ion Exclusion

candy using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14983

Ion Exclusion

Orange juice analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14981

Ion Exclusion

Apple Juice analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14979

Ion Exclusion

Sugar analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14977

Ion Exclusion

Saccharide analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14975

Carbohydrates analysis using Rezex RAM

14974

Ion Exclusion

Monosaccharides with organic acids using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14969

Ion Exclusion

Sugar alcohols using Rezex RPM

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

14968

Ion Exclusion

Wood saccharides using Rezex RPM

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

14967

Saccharides using Rezex RAM

14966

Ion Exclusion

Carbohydrate Mix 3 (AL0-3037)

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14747

Ion Exclusion

Carbohydrate Mix 2 (AL0-3036)

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

14746

Normal Phase

Amino Batch E3 - Simple Sugars

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14322

Normal Phase

Amino Batch E2 - Simple Sugars

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14321

Normal Phase

Amino Batch E1 - Simple Sugars

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14320

Normal Phase

Complex Sugars on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14309

Normal Phase

Wine on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14295

Normal Phase

Cereal on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14294

Normal Phase

Protein Bar on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14293

Normal Phase

Root Beer on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14291

Normal Phase

Orange Juice on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14290

Normal Phase

Simple Sugars (#5) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14287

Normal Phase

Simple Sugars (#3) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14285

Normal Phase

Simple Sugars (#2) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14284

Normal Phase

Simple Sugars (#1) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14283

Normal Phase

Mixture of Sugars and Sugar Alcohols on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14282

Normal Phase

Sugars in Orange on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14281

Normal Phase

Sugars in Apple on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14280

Malto-oligosaccharides

13556

Fructo-oligosaccharides

13555

Ion Exclusion

Sugars in Honey on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

6523

Ion Exclusion

Amino Sugars

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

5514

Ion Exclusion

Carbohydrates

Rezex RNM-Carbohydrate Na+ (8%), LC Column 300 x 7.8 mm, Ea

5510

Ion Exclusion

Saccharides

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

5508

Ion Exclusion

Apple Juice

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

5505

Ion Exclusion

Saccharides

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

5504

Ion Exclusion

Honey

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

5503

Ion Exclusion

Sugars in Cucumber Juice on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

3147

Ion Exclusion

HPLC of Carbohydrates from Yellow-Seeded Canola on Rezex RSO

Rezex RSO-Oligosaccharide Ag+ 4%, LC Column 200 x 10 mm, Ea

2696