Amino Sugars
LC Conditions
Column
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
Brand
Rezex
Part No
00H-0138-K0
Phase Name
ROA-Organic Acid H+ (8%)
Elution Type
Isocratic
Mobile Phase
A: 1% Phosphoric acid
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
0.60 mL/min
Temperature
22°C
Detection
Refractive Index (RI) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Carbo-H 4 x 3.0mm, 10/Pk Part No.: AJ0-4490 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Glucose
- 2. N-Acetylglucoseamine
- 3. N-Acetylgalactosamine
-OEChem-06211003162D<br><br> 24 23 0 1 0 0 0 0 0999 V2000<br> 5.4641 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 -0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7320 0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 7.1962 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2002 0.6750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3342 -0.6750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0662 -0.6750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4682 0.6750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5947 0.7249 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7976 0.7249 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 7 1 0 0 0 0<br> 1 19 1 0 0 0 0<br> 2 8 1 0 0 0 0<br> 2 20 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 22 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 4 23 1 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 6 12 2 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 9 15 1 0 0 0 0<br> 10 12 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 11 17 1 0 0 0 0<br> 11 18 1 0 0 0 0<br> 12 21 1 0 0 0 0<br>M END
Compound Name
Glucose
CID
24749
Molecular Formula
C6H12O6
Molecular Weight
180
No. Hydrogen Bond Acceptors
6
No. Hydrogen Bond Donors
5
Similar Applications
Hydrophilic Interaction
15 Sugars Analyzed by LC-RI using Luna Omega SUGAR
Luna Omega 3 µm SUGAR 100 Å, LC Column 150 x 4.6 mm, Ea
25453
Normal Phase
Complex Sugars on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
17010
Ion Exclusion
Beer Well Drop on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16647
Ion Exclusion
25 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16646
Ion Exclusion
10 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16645
Ion Exclusion
6 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16644
Ion Exclusion
Yeast Prop. on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16643
Application Specific
TMS Sugars on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16248
Ion Exclusion
Sialic acid mix using Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
15769
Ion Exclusion
Saccharide analysis using Rezex RHM
Rezex RHM-Monosaccharide H+ (8%), LC Column 300 x 7.8 mm, Ea
14991
Ion Exclusion
Fermentation yeast sample using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14990
Ion Exclusion
Fermentation sample #3 using Rexex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14989
Ion Exclusion
Fermentation sample #2 using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14988
Ion Exclusion
Fermentation sample #1 using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14987
Ion Exclusion
Saccharide analysis using Rezex RPM
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
14985
Ion Exclusion
candy using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14983
Ion Exclusion
Orange juice analysis using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14981
Ion Exclusion
Apple Juice analysis using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14979
Ion Exclusion
Sugar analysis using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14977
Ion Exclusion
Saccharide analysis using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14975
Carbohydrates analysis using Rezex RAM
14974
Ion Exclusion
Monosaccharides with organic acids using Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
14969
Ion Exclusion
Sugar alcohols using Rezex RPM
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
14968
Ion Exclusion
Wood saccharides using Rezex RPM
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
14967
Saccharides using Rezex RAM
14966
Ion Exclusion
Carbohydrate Mix 3 (AL0-3037)
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14747
Ion Exclusion
Carbohydrate Mix 2 (AL0-3036)
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
14746
Normal Phase
Amino Batch E3 - Simple Sugars
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14322
Normal Phase
Amino Batch E2 - Simple Sugars
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14321
Normal Phase
Amino Batch E1 - Simple Sugars
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14320
Normal Phase
Complex Sugars on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14309
Normal Phase
Wine on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14295
Normal Phase
Cereal on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14294
Normal Phase
Protein Bar on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14293
Normal Phase
Root Beer on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14291
Normal Phase
Orange Juice on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14290
Normal Phase
Simple Sugars (#5) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14287
Normal Phase
Simple Sugars (#3) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14285
Normal Phase
Simple Sugars (#2) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14284
Normal Phase
Simple Sugars (#1) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14283
Normal Phase
Mixture of Sugars and Sugar Alcohols on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14282
Normal Phase
Sugars in Orange on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14281
Normal Phase
Sugars in Apple on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14280
Malto-oligosaccharides
13556
Fructo-oligosaccharides
13555
Ion Exclusion
Sugars in Honey on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
6523
Ion Exclusion
Amino Sugars
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
5514
Ion Exclusion
Carbohydrates
Rezex RNM-Carbohydrate Na+ (8%), LC Column 300 x 7.8 mm, Ea
5510
Ion Exclusion
Saccharides
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
5508
Ion Exclusion
Apple Juice
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
5505
Ion Exclusion
Saccharides
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
5504
Ion Exclusion
Honey
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
5503
Ion Exclusion
Sugars in Cucumber Juice on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
3147
Ion Exclusion
HPLC of Carbohydrates from Yellow-Seeded Canola on Rezex RSO
Rezex RSO-Oligosaccharide Ag+ 4%, LC Column 200 x 10 mm, Ea
2696