Glucocorticoids - Sphereclone vs. Spherisorb Comparison
LC Conditions
Column
SphereClone 5 µm ODS(2) 80 Å, LC Column 250 x 4.6 mm, Ea
Brand
SphereClone
Part No
00G-4144-E0
Phase Name
ODS(2)
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
50
50
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Uracil
- 2. Prednisolone
- 3. Betamethasone
- 4. Prednisolone 21-acetate
- 5. Betamethasone 17-valerate
-OEChem-06211003142D<br><br> 12 12 0 0 0 0 0 0 0999 V2000<br> 2.0000 -0.6900 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.6900 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.6900 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.8100 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 1.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 2 0 0 0 0<br> 2 6 2 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 11 1 0 0 0 0<br>M END
Compound Name
Uracil
CID
1174
Molecular Formula
C4H4N2O2
Molecular Weight
112
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Similar Applications
Hydrophilic Interaction
HILIC Separation of Nucleobases using a Diol HILIC column
Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea
28694
Reversed Phase
ABN7 using Method Transfer Scaling Calculator on Luna Omega 5 µm C18 250 x 4.6 mm with Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26804
Reversed Phase
ABN7 using Method Transfer Scaling Calculator on Luna Omega 3 µm C18 150 x 4.6 mm with Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26803
Reversed Phase
ABN7 using Method Transfer Scaling Calculator on Luna Omega 1.6 µm C18 50 x 2.1 mm with Agilent 1260 Binary UHPLC
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
26802
Phen870 on XBridge BEH C18 5 µm, 250 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
26735
Phen870 on XBridge BEH C18 5 µm, 250 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
26734
Phen870 on XBridge BEH C18 5 µm, 250 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
26733
Phen870 on Agilent Zorbax SB-C18 5 µm 250 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
26732
Phen870 on Agilent Zorbax SB-C18 5 µm 250 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
26731
Phen870 on Agilent Zorbax SB-C18 5 µm 250 x 4.6 mm (Batch
- using Agilent 1260 Binary UHPLC
26730
Reversed Phase
Phen870 on Luna Omega 5 µm C18 250 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26729
Reversed Phase
Phen870 on Luna Omega 5 µm C18 250 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26728
Reversed Phase
Phen870 on Luna Omega 5 µm C18 250 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26727
Phen870 on Waters XBridge 3.5 µm 150 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
26726
Phen870 on Waters XBridge 3.5 µm 150 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
26725
Phen870 on Waters XBridge 3.5 µm 150 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
26724
Phen870 on Agilent Zorbax SB-C18 3.5 µm 150 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
26723
Phen870 on Agilent Zorbax SB-C18 3.5 µm 150 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
26722
Phen870 on Agilent Zorbax SB-C18 3.5 µm 150 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
26721
Reversed Phase
Phen870 on Luna 3 µm C18(2) 150 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna 3 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26720
Reversed Phase
Phen870 on Luna 3 µm C18(2) 150 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna 3 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26719
Reversed Phase
Phen870 on Luna 3 µm C18(2) 150 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna 3 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26718
Reversed Phase
Phen870 on Luna Omega 3 µm C18 150 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26717
Reversed Phase
Phen870 on Luna Omega 3 µm C18 150 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26716
Reversed Phase
Phen870 on Luna Omega 3 µm C18 150 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26715
Reversed Phase
Phen870 on Luna Omega 5 µm C18 150 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26714
Reversed Phase
Phen870 on Luna Omega 5 µm C18 150 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26713
Reversed Phase
Phen870 on Luna Omega 5 µm C18 150 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26712
Reversed Phase
Phen870 on Luna 5 µm C18(2) 150 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26711
Reversed Phase
Phen870 on Luna 5 µm C18(2) 150 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26710
Reversed Phase
Phen870 on Luna 5 µm C18(2) 150 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26709
Reversed Phase
Phen870 on Luna Omega 3 µm C18 50 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
26708
Reversed Phase
Phen870 on Luna Omega 3 µm C18 50 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
26707
Reversed Phase
Phen870 on Luna Omega 3 µm C18 50 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
26706
Reversed Phase
Phen870 on Luna 3 µm C18(2) 50 x 4.6 mm (Batch 3) using Agilent 1260 Binary UHPLC
Luna 3 µm C18(2) 100 Å, LC Column 50 x 4.6 mm, Ea
26705
Reversed Phase
Phen870 on Luna 3 µm C18(2) 50 x 4.6 mm (Batch 2) using Agilent 1260 Binary UHPLC
Luna 3 µm C18(2) 100 Å, LC Column 50 x 4.6 mm, Ea
26704
Reversed Phase
Phen870 on Luna 3 µm C18(2) 50 x 4.6 mm (Batch 1) using Agilent 1260 Binary UHPLC
Luna 3 µm C18(2) 100 Å, LC Column 50 x 4.6 mm, Ea
26691
Reversed Phase
Extraction of 5-Fluorouracil from Human Serum Using Strata-X PRO SPE on a Kinetex 2.6 μm PS C18 (ESI -Ve Mode)
Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea
25778
Reversed Phase
Extraction of Uracil and Dihydrouracil from Human Serum Using Strata-X PRO SPE Using Kinetex 2.6 μm PS C18 (ESI +Ve mode)
Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea
25777
Reversed Phase
Analysis of Uracil and metabolites on Kinetex 2.6 um PS C18 150x3.0 Column
Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea
25589
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7914) (Methanol)
25435
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (Methanol)
25434
Reversed Phase
ABN7 in Formic Acid Screening on 2.6u Kinetex PS C18 50x4.6mm (0361) (Acetonitrile)
Kinetex 2.6 µm PS C18 100 Å, LC Column 50 x 4.6 mm, Ea
25424
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7914) (Acetonitrile)
25422
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7306) (Acetonitrile)
25417
Reversed Phase
100 Make and Break Connections with SecurityLINK on Kinetex C18
Kinetex 1.3 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
25103
SecurityLINK vs Viper Zero Dead Volume Connections on Agilent Eclipse Plus C18 RRHD
25096
Reversed Phase
SecurityLINK VS Viper Zero Dead Volume Connections on Luna Omega C18
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
25095
Reversed Phase
ABN7 on Luna Omega 1.6u PS C18 50x2.1mm
Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA
23707
Reversed Phase
Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22803
Reversed Phase
Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22734
Reversed Phase
Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22718
Reversed Phase
Aeris Batch Reproducalbity #3: SRM 870 on Aeris PEPTIDE 1.7u XB-C18 50x4.6mm
Aeris 1.7 µm PEPTIDE XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19909
Reversed Phase
Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea
19812
Reversed Phase
Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea
19811
Reversed Phase
Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea
19810
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18803
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18802
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18801