FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Documents
Determination of Cylindrospermopsin and Anatoxin-a in Drinking Water by UHPLC-MS/MS using a Luna Omega 1.6 µm Polar C18 (EPA Method 545)
Cyanotoxins like Cylindrospermopsin or Anatoxin-a are produced by blue-green algae and can be very harmful to humans and animals especially through consumption of contaminated water. As environmental conditions change and promote harmful algal blooms growth, drinking and surface water testing becomes incredibly important to ensure a community’s safety. In this application, the water soluble and highly polar cyanotoxins Cylindrospermopsin and Anatoxin-a were analyzed via UHPLC-MS/MS using a Luna Omega 1.6 µm Polar C18. The 100 % aqueous stability combined with enhanced polar retention provided by the Luna Omega Polar C18 allows for excellent retention of the target toxins as well as the isotopically labeled internal standards. Acknowledgement: We would especially like to thank David Schiessel and Babcock Laboratories for their support and use of their method, system, and standards for this application.

Determination of Cylindrospermopsin and Anatoxin-a in Drinking Water by UHPLC-MS/MS using a Luna Omega 1.6 µm Polar C18 (EPA Method 545)

Cyanotoxins like Cylindrospermopsin or Anatoxin-a are produced by blue-green algae and can be very harmful to humans and animals especially through consumption of contaminated water. As environmental conditions change and promote harmful algal blooms growth, drinking and surface water testing becomes incredibly important to ensure a community’s safety. In this application, the water soluble and highly polar cyanotoxins Cylindrospermopsin and Anatoxin-a were analyzed via UHPLC-MS/MS using a Luna Omega 1.6 µm Polar C18. The 100 % aqueous stability combined with enhanced polar retention provided by the Luna Omega Polar C18 allows for excellent retention of the target toxins as well as the isotopically labeled internal standards. Acknowledgement: We would especially like to thank David Schiessel and Babcock Laboratories for their support and use of their method, system, and standards for this application.
Document Type:
Technical Notes
Target Industries:
Techniques:
Separation Modes:
Reversed Phase