For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Product Information
Phase Detail
Rezex RAM-Carbohydrate Ag+ (8%) Ion Exclusion HPLC Columns
Rezex RAM-Carbohydrate Ag+ (8%) Ion Exclusion HPLC Columns is packed with an 8 % cross-linked silver ionic form ion exclusion media

Rezex RAM-Carbohydrate Ag+ (8%) Ion Exclusion HPLC Columns

  • 8 % cross-linked silver ionic form
  • Unique selectivity complementary to other Rezex column types

Select Applications on Rezex HPLC Columns

Saccharides

Column:
Rezex RAM-Carbohydrate
Dimension:
300 x 7.8 mm
Part No.:
00H-0131-K0
Mobile Phase:
Water
Flow Rate:
0.6 mL/min
Temperature:
75 °C
Detection:
ELSD
Sample:
1. Melezitose
2. Mannose
3. Maltose
4. Fructose
5. Glucose

Carbohydrates

Column:
Rezex RAM-Carbohydrate
Dimension:
300 x 7.8 mm
Part No.:
00H-0131-K0
Mobile Phase:
Water
Flow Rate:
0.6 mL/min
Injection Volume:
5 µL
Temperature:
80 °C
Detection:
ELSD
Sample:
1. Sucrose
2. Glucose
3. Arabinose
4. Ribose

Applications (partial list)

Call us for assistance in selecting the right column for your needs!

Compound App ID No.
Arabinose 14974
Fructose 14966
Glucose 14966, 14974
Maltose 14966
Mannose 14966

Compound App ID No.
Melezitose 14966
Ribose 14974
Ribitol 14966
Sucrose 14974

Specifications and Operating Recommendations

RAM Carbohydrate
Part No. 00H-0131-K0
Ionic Form Silver
Standard Dimensions 300 x 7.8 mm
Matrix Sulfonated Styrene Divinyl Benzene
Cross Linking 8 %
Particle Size (μm) 8
Min. Efficiency (p/m) based on last peak 35,000
Typical Pressure (psi @ Testing Flow Rate) 285
Max. Pressure (psi @ Max Flow Rate) 1,000
Max. Flow Rate (mL/min) 1.0
Max. Temperature (°C) 85
Typical Mobile Phase Water
pH Range Neutral
Guard Column Part 03B-0131-K0
Cleaning, Regeneration and Storage
Organic Modifiers (Max) 5 % Methanol, IPA, EtOH
Inorganic Modifiers 2 % Silver Nitrate
Avoid Acids, Bases, Non-Silver Salts or
Metal Ions, > 30 % Acetonitrile
Cleaning Solvent 100 % Water
Flow Rate(mL/min) 0.4
Temperature (°C) 85
Duration (hrs) 12
Regeneration Solvent 0.1 M AgNO3
Flow Rate (mL/min) 0.2
Temperature (°C) 85
Duration (hrs) 4-16
Ship/Storage Solvent Water