Sample Prep|Brands|Strata-Mag RP Magnetic Beads Extraction
SP
412
3169
strata-mag-magnetic-bead-extraction
strata-mag-rp

Strata-Mag RP Magnetic Beads Extraction

Strata-Mag RP transforms reversed-phase extraction, utilizing magnetic bead technology to deliver reproducible results at lower cost with seamless integration into automated platforms. SPE challenges like channeling and plugging are eliminated. Clinical research laboratories can now transition to fully automated sample preparation to achieve higher throughput and greater efficiency with consistent, reliable extraction performance.

  • Seamless integration into automated sample preparation
  • Reproducible results and high throughput
  • Greater efficiency with consistent, reliable extraction at lower cost per sample
#f2f5f9
smooth-scroll-vertical-tabs

Order

Overview

Key Application and Benefit Highlights

Manual Workflow

Ideal for:

  • Method development
  • Low-to medium-throughput testing
  • Laboratories with limited automation capabilities

Automated Workflow

Ideal for:

  • Routine LC-MS/MS testing
  • Increased efficiency and higher throughput
  • Fully automated sample preparation

Say goodbye to channeling, plugging, and SPE bottlenecks.

Laboratories seeking flexibility and reliable extraction performance while transitioning seamlessly from low-volume processing to fully automated operation can rely on Strata-Mag RP for consistency and scalability.

Which workflow is the best for your lab?

Manual Extraction Workflow

rT3 Extraction Workflow – Manual
  • Operator manually performs all liquid-handling steps. ​
  • Magnetic beads remain in the same well during bind, wash, and elution steps.​
  • Magnetic rack retains the beads while liquids are removed and replaced​
  • Same Strata-Mag RP extraction chemistry​

Semi Automated Extraction Workflow (KingFisher)

rT3 Extraction Workflow – Semi Automated (KingFisher)
  • Sample and reagents are prepared and pre-filled before the run​
  • Magnetic head moves the beads through bind, wash, and elution solutions​
  • Reduces manual liquid handling during the extraction run​
  • Same Strata-Mag RP extraction chemistry​

Automated Extraction Workflow (Beckman Biomek)

  • Liquid handler automates reagent addition and liquid removal​
  • Magnetic beads remain in the same well during bind, wash, and elution steps.​
  • Minimizes operator intervention during the extraction workflow​
  • Same Strata-Mag RP extraction chemistry​

Comparison Between Manual and Automated Methods for rT3 Analysis in Human Serum

Absolute recovery was calculated by comparing the rT3 peak areas of pre-extraction-spiked samples with those of post-extraction-spiked samples. Matrix effects were assessed by comparing post-spike serum samples with neat standard solutions at the same concentration.
75
dark-gray text-white
Workflow
1
1
false
left
top
Absolute Recovery (%)
1
1
false
left
top
RSD (%)
1
1
false
left
top
Matrix Suppression (%)
1
1
false
left
top
Preparation Time
1
1
false
left
top
Manual
1
1
false
left
top
64.0
1
1
false
left
top
16.5 (n=6)
1
1
false
left
top
34.9
1
1
false
left
top
2 to 2.5 hrs.
1
1
false
left
top
Automated
1
1
false
left
top
67.2
1
1
false
left
top
4.9 (n=4)
1
1
false
left
top
14.5
1
1
false
left
top
1 to 1.5 hrs.
1
1
false
left
top

Frequently Asked Questions About Strata-Mag RP

What is Strata-Mag RP?

Strata-Mag RP is a reversed-phase magnetic bead sample preparation technology designed for LC-MS workflows. It combines the selectivity of reversed-phase extraction with the simplicity of magnetic separation, enabling efficient sample cleanup and easy integration with automated laboratory workflows. It is particularly well suited for hydrophobic and weakly polar analytes commonly measured in clinical laboratories.

Which clinical applications is Strata-Mag RP best suited for?

Strata-Mag RP is optimized for clinical LC-MS applications involving hydrophobic analytes, including reverse triiodothyronine (rT3), steroid hormones. These assays often demand effective matrix cleanup, high reproducibility, and scalable workflows to support growing testing volumes in clinical laboratories.

How does Strata-Mag RP compare with traditional SPE?

Unlike traditional SPE methods that rely on vacuum manifolds or positive-pressure systems, Strata-Mag RP uses magnetic separation to simplify extraction workflows. This can reduce hands-on time, minimize solvent consumption, eliminate flow-rate variability, and make automation easier while maintaining the sample cleanliness and performance expected from chromatography-based extraction methods.

Can Strata-Mag RP be automated?

Yes. Strata-Mag RP was developed with automation compatibility in mind. The magnetic separation workflow can be incorporated into manual, semi-automated, or fully automated sample preparation platforms, helping laboratories increase throughput while reducing operator-to-operator variability.

What benefits does Strata-Mag RP provide to clinical laboratories?

Strata-Mag RP helps clinical laboratories simplify sample preparation while improving operational efficiency. Key benefits include:

  • Reduced hands-on processing time
  • Improved workflow reproducibility
  • Lower dependence on highly skilled operators
  • Easy implementation on automated platforms
  • Lower solvent and consumable usage
  • Scalable processing for high-throughput testing environments

These advantages can help laboratories meet increasing sample volume demand for clinical assays while maintaining high data quality.