FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Product Information
Phase Detail
Claricep Spherical Silica
Claricep spherical CS silica flash columns provide significant performance over traditional flash columns on the market

Claricep Spherical Silica

  • Higher Resolution and Better Purification for 20 µm
  • Lower Backpressure, Faster Flow Rate, and Higher Loading Capacity for 20-35 µm

Sample Information

The sample is a colorless liquid, with about 60 % target compound by weight. Dissolve 0.2 mL of sample into 1.5 mL ethanol sonication.

Flash Conditions

Column A:
Claricep Spherical Silica (20-35 µm, 100 Å, 12 g, 2 columns in tandem)
Column B:
Claricep Spherical Silica (20 µm, 100 Å, 12 g, 2 columns in tandem)
Mobile Phase:
A: Hexane
B: Ethanol
Gradient:
Time (min)
0
20
 
% B
5
55
Flow Rate:
12 mL/min
Detection:
UV @ 254/220 nm
Sample Loading:
0.2 mL

Small molecular weight with UV absorption of methacrylic acid ester R: no UV absorption

 

CLARICEP Spherical Silica Screw-on Columns

The Screw-on series of Flash columns are a new feature that allows the user to load a solid phase, viscous phase, or simply open the cap for a more user friendly analysis.

Which Screw-on Series should I order ?

CLARICEP i-Series

The i-Series features a managed column head space with a secured screw-on lid. This new design allows either loading of liquid samples directly onto the column head or loading of impregnated solid sample directly into the space. Users will benefit from:

  • Choice of loading method based on sample properties
  • Narrow band for liquid samples because of wide loading area
  • Dry-loading of solid impregnated samples minimizes band broadening
  • Customized loading method upon user preference

Ordering Information
Part Number starts with “SN”. As an example, to order SS130020-0 in i-series, Part Number to order is SN-SS130020-0

claricep i-series

CLARICEP c-Series

The c-Series shares the same design, but the column outlet does not have a luer lock structure, this simplifies tubing connection across various flash systems.

Compatible with instruments from the following:
  • Agela Technologies
  • Buchi
  • Grace
  • Interchim
  • Other brands

Ordering Information
Part Number starts with “C”. As an example, to order SS130020-0 in c-series, Part Number to order is C-SS130020-0

claricep c-series

CLARICEP s-Series

The s-Series columns are fully packed without a head void. In addition, the Luer lock fittings for both inlet and outlet allows easy operation of tandem columns or the coupling of a loading cartridge.

Compatible with instruments from the following:
  • Biotage

Ordering Information
Part Number starts with “S”. As an example, to order SS130020-0 in s-series, Part Number to order is S-SS130020-0

claricep s-series

Purification of a Sample with Methacrylic Acid Ester Target Compound