EPA Method 555A, Chlorinated Acids
LC Conditions
Official Method
EPA 555
Column
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4375-E0
Phase Name
Hydro-RP
Elution Type
Gradient
Mobile Phase
A: 25mM Phosphoric Acid
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
90
10
2
20
10
90
3
30
10
90
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, AQ C18 4 x 3.0mm, 10/Pk Part No.: AJ0-7511 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Picloram
- 2. Chloramben
- 3. Dicamba
- 4. Bentazon
- 5. 2,4-D
- 6. Dichloroprop
- 7. 2, 4, 5-TP
- 8. Acifluorfen
-OEChem-06211003152D<br><br> 16 16 0 0 0 0 0 0 0999 V2000<br> 2.8660 1.0000 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.0000 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.0000 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 2 11 1 0 0 0 0<br> 3 12 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 16 1 0 0 0 0<br> 5 13 2 0 0 0 0<br> 6 10 2 0 0 0 0<br> 6 12 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 14 1 0 0 0 0<br> 7 15 1 0 0 0 0<br> 8 9 2 0 0 0 0<br> 8 11 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 10 13 1 0 0 0 0<br> 11 12 2 0 0 0 0<br>M END
Compound Name
Picloram
CID
15965
Molecular Formula
C6H3Cl3N2O2
Molecular Weight
241
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Similar Applications
Application Specific
EPA 8151 by GC/ECD on ZB-CLPesticides-2 (Hydrogen Gas)
Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
23633
Application Specific
EPA 8151 by GC/ECD on ZB-CLPesticides-1 (Hydrogen Gas)
Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea
23632
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-XLB-HT 30x0.32x0.25 (Dual column)
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
19283
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-35-HT 30x0.32x0.25 (Dual column)
Zebron ZB-35HT, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
19282
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-XLB-HT(Dual column)
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18789
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-35-HT(Dual column)
Zebron ZB-35HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18788
Application Specific
Methylated Chlorinated Acids (EPA 515.2) Mix # 2 on ZB-MR2
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea
17584
Application Specific
EPA Method 8151A on MR1 (Carrier Gas: Helium)
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16764
Standard
EPA Method 8151A on ZB-35 (Carrier Gas: Helium)
Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16758
Application Specific
EPA 8151A on MR2 (Carrier Gas: Helium)
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16576
Application Specific
EPA 8151A on MR2 (Carrier Gas: Hydrogen)
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16566
Standard
EPA 8151A on ZB-35 (Carrier Gas: Hydrogen)
Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16562
Standard
EPA 8151A Chlorinated Herbicides on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
16464
Application Specific
EPA Method 8151: Chlorinated Herbicides on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16185
Application Specific
Screening of Pesticides by GC-MS on ZB-MultiResidue-1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16184
Application Specific
Screening of Pesticide by GC/MS on ZB-MR2
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea
16183
Standard
EPA Method 515.2: Chlorinated Acids on ZB-1701
Zebron ZB-1701, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15791
Standard
EPA Method 515.2: Chlorinated Acids on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15790
Reversed Phase
EPA Method 644, Picloram
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
14492
Reversed Phase
EPA Method 555A, Chlorinated Acids
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea
14475