Estriol by LCMS using Gemini 3um C6-Phenyl 50x2mm
LC Conditions
Column
Gemini 3 µm C6-Phenyl 110 Å, LC Column 50 x 2 mm, Ea
Brand
Gemini
Part No
00B-4443-B0
Phase Name
C6-Phenyl
Elution Type
Gradient
Mobile Phase
A: H2O + 0.5 mM ammonium hydroxide
B: MeOH + 0.5 mM ammonium hydroxide
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
2
0.5
80
20
3
3.5
10
90
4
5
10
90
5
5.1
80
20
6
6
80
20
Flow Rate
0.50 mL/min
Temperature
22°C
Detection
Tandem Mass Spec (MS-MS) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Estriol
- 2. Estriol-d3
-OEChem-06211003152D<br><br> 45 48 0 1 0 0 0 0 0999 V2000<br> 9.1857 2.1128 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.4586 0.3575 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5357 -2.1948 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9288 0.8575 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 7.9288 -0.1425 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 7.0628 -0.6425 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.1968 -0.1425 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 8.8750 1.1623 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 7.0628 1.3575 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8750 -0.4472 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4586 0.3575 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.1968 0.8575 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0789 -1.6840 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9288 1.8575 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2868 -0.6493 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1808 -2.2117 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2787 -1.6909 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3599 -0.0852 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3433 -2.2406 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4120 -0.6132 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4037 -1.6981 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0188 -0.9877 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8022 -1.0618 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9329 0.2825 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4875 1.2585 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4613 1.8325 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6643 1.8325 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6240 -1.0141 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4124 -0.7564 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7404 0.9098 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9847 1.4401 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5862 0.7499 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2969 -2.2644 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6880 -1.5685 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5488 1.8575 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9288 2.4775 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3088 1.8575 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7835 -2.6877 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5818 -2.6846 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7924 2.2406 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.7687 -0.1794 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3719 0.5347 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3457 -2.8606 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8787 -0.2970 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.8827 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8 1 1 1 0 0 0<br> 1 40 1 0 0 0 0<br> 11 2 1 6 0 0 0<br> 2 41 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 3 45 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 14 1 1 0 0 0<br> 5 6 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 5 22 1 6 0 0 0<br> 6 7 1 0 0 0 0<br> 6 13 1 0 0 0 0<br> 6 23 1 1 0 0 0<br> 7 12 1 0 0 0 0<br> 7 15 1 0 0 0 0<br> 7 24 1 6 0 0 0<br> 8 11 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 12 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 10 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 13 33 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 35 1 0 0 0 0<br> 14 36 1 0 0 0 0<br> 14 37 1 0 0 0 0<br> 15 17 2 0 0 0 0<br> 15 18 1 0 0 0 0<br> 16 17 1 0 0 0 0<br> 16 38 1 0 0 0 0<br> 16 39 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 18 42 1 0 0 0 0<br> 19 21 2 0 0 0 0<br> 19 43 1 0 0 0 0<br> 20 21 1 0 0 0 0<br> 20 44 1 0 0 0 0<br>M END
Compound Name
Estriol
CID
5756
Molecular Formula
C18H24O3
Molecular Weight
288
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
Estradiol and estrone analysis by LCMS using Gemini 3um NX-C18 50x2mm
Gemini 3 µm NX-C18 110 Å, LC Column 50 x 2 mm, Ea
20653