Guaifenesin on Lux 5µm i-Cellulose-5 250x4.6mm
LC Conditions
Column
Lux 5 µm i-Cellulose-5, LC Column 250 x 4.6 mm, EA
Brand
Lux
Part No
00G-4756-E0
Phase Name
i-Cellulose-5
Elution Type
Isocratic
Mobile Phase
A: 0.1% DEA in n-Hexane
B: 0.1% DEA in Ethanol
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
Flow Rate
1.50 mL/min
Temperature
27°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (20°C)
Detection Info
Sample Notes
Resolution = 5.32 Selectivity = 1.24
Order Items Used in This Application
- 1. Guaifenesin
- 2. Guaifenesin
-OEChem-06211003152D<br><br> 28 28 0 1 0 0 0 0 0999 V2000<br> 4.5981 -0.1550 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.8450 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.8450 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.1550 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.3450 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 0.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.9650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6762 -0.2376 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0747 0.4527 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5422 1.2624 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9407 1.9527 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -1.3450 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -2.9650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -2.9650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.7750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 3.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -1.1181 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.9650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -2.1919 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 6 1 0 0 0 0<br> 1 8 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 22 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 25 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 14 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 15 1 0 0 0 0<br> 6 16 1 0 0 0 0<br> 6 17 1 0 0 0 0<br> 7 18 1 0 0 0 0<br> 7 19 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 10 2 0 0 0 0<br> 9 11 2 0 0 0 0<br> 10 12 1 0 0 0 0<br> 10 20 1 0 0 0 0<br> 11 13 1 0 0 0 0<br> 11 21 1 0 0 0 0<br> 12 13 2 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 26 1 0 0 0 0<br> 14 27 1 0 0 0 0<br> 14 28 1 0 0 0 0<br>M END
Compound Name
Guaifenesin
CID
3516
Molecular Formula
C10H14O4
Molecular Weight
198
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
Cold medicine compounds on Kinetex 2.6 µm EVO C18
Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA
23036