Sugars in Orange on Luna Amino

Sugars in Orange on Luna Amino
LC Conditions
Column

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

Brand

Luna

Part No

00G-4378-E0

Phase Name

NH2

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

80

20

Flow Rate

3.00 mL/min

Temperature

40°C

Detection

Refractive Index (RI) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, NH2 4 x 3.0mm, 10/Pk Part No.: AJ0-4302 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
00G-4378-E0

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Fructose
  • 2. Glucose
  • 3. Sucrose
-OEChem-06211003152D<br><br> 24 23  0     1  0  0  0  0  0999 V2000<br>    5.1350   -1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369    0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671   -1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.5991   -0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -0.2500    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    4.2690    0.2500    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    6.0010    0.2500    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    3.4030   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7331    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6720   -0.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8059    0.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5380    0.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0044   -0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8015   -0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.1316    0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3346    0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5380    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.1360    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  7  1  1  6  0  0  0<br>  1 18  1  0  0  0  0<br>  8  2  1  1  0  0  0<br>  2 21  1  0  0  0  0<br>  9  3  1  6  0  0  0<br>  3 22  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 23  1  0  0  0  0<br>  5 11  2  0  0  0  0<br>  6 12  1  0  0  0  0<br>  6 24  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 11  1  0  0  0  0<br>  9 15  1  0  0  0  0<br> 10 16  1  0  0  0  0<br> 10 17  1  0  0  0  0<br> 11 12  1  0  0  0  0<br> 12 19  1  0  0  0  0<br> 12 20  1  0  0  0  0<br>M  END
Compound Name

Fructose

CID

5984

Molecular Formula

C6H12O6

Molecular Weight

180

No. Hydrogen Bond Acceptors

6

No. Hydrogen Bond Donors

5

Similar Applications

Hydrophilic Interaction

15 Sugars Analyzed by LC-RI using Luna Omega SUGAR

Luna Omega 3 µm SUGAR 100 Å, LC Column 150 x 4.6 mm, Ea

25453

Ion Exclusion

Saccharide analysis using Rezex RHM

Rezex RHM-Monosaccharide H+ (8%), LC Column 300 x 7.8 mm, Ea

14991

Ion Exclusion

Fermentation yeast sample using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14990

Ion Exclusion

Fermentation sample #3 using Rexex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14989

Ion Exclusion

Fermentation sample #2 using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14988

Ion Exclusion

Fermentation sample #1 using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14987

Ion Exclusion

Saccharide analysis using Rezex RPM

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

14985

Ion Exclusion

candy using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14983

Ion Exclusion

Orange juice analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14981

Ion Exclusion

Apple Juice analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14979

Ion Exclusion

Sugar analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14977

Ion Exclusion

Saccharide analysis using Rezex RCM

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14975

Ion Exclusion

Monosaccharides with organic acids using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14969

Saccharides using Rezex RAM

14966

Ion Exclusion

Carbohydrate Mix 3 (AL0-3037)

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

14747

Ion Exclusion

Carbohydrate Mix 2 (AL0-3036)

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

14746

Normal Phase

Amino Batch E3 - Simple Sugars

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14322

Normal Phase

Amino Batch E2 - Simple Sugars

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14321

Normal Phase

Amino Batch E1 - Simple Sugars

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14320

Normal Phase

Wine on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14295

Normal Phase

Cereal on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14294

Normal Phase

Protein Bar on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14293

Normal Phase

Root Beer on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14291

Normal Phase

Orange Juice on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14290

Normal Phase

Simple Sugars (#6) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14288

Normal Phase

Simple Sugars (#4) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14286

Normal Phase

Simple Sugars (#3) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14285

Normal Phase

Simple Sugars (#2) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14284

Normal Phase

Simple Sugars (#1) on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14283

Normal Phase

Mixture of Sugars and Sugar Alcohols on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14282

Normal Phase

Sugars in Orange on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14281

Normal Phase

Sugars in Apple on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14280

Ion Exclusion

Sugars in Honey on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

6523

Ion Exclusion

Carbohydrates

Rezex RNM-Carbohydrate Na+ (8%), LC Column 300 x 7.8 mm, Ea

5510

Ion Exclusion

Saccharides

Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea

5508

Ion Exclusion

Apple Juice

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

5505

Ion Exclusion

Saccharides

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

5504

Ion Exclusion

Honey

Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea

5503

Ion Exclusion

Sugars in Cucumber Juice on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

3147