For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
23560
Separation Mode: Reversed Phase
Reversed Phase
Biphenyl
HPLC
Hypnotics and Sedatives
Forensics/Toxicology
Clinical
Pharmaceutical/Biopharmaceutical
Therapeutic / Clinical
Therapeutic / Clinical
Therapeutic / Clinical
Therapeutic / Clinical

Applications

7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
Analytes
16-MAM
27-Aminoclonazepam
3alpha-hydroxyalprazolam
4Alprazolam
5Amitriptyline
6Amphetamine
7Benzoylecgonine
8Buprenorphine
9Carisoprodol
10Citalopram
11Codeine
12Cotinine
13Diazepam
14EDDP
15Fentanyl
16Fluoxetine
17Gabapentin
18Hydrocodone
19Hydromorphone
20Imipramine
21Lorazepam
22MDMA
23Meperidine
24Meprobamate
25Methadone
26Methamphetamine
27Methylphenidate
28Morphine
29Naloxone
30Norbuprenorphine
31Nordiazepam
32Norfentanyl
33Norhydrocodone
34Noroxycodone
35Normorphine
36Nortriptyline
37O-Desmethyltramadol
38Oxycodone
39Oxymorphone
40Paroxetine
41PCP
42Pregabalin
43Sertraline
44Tapentadol
45Temazepam
46Tramadol
47Zolpidem
48Zolpidem-4-carboxylic Acid
Compound Name
6-Acetylmorphine
CID
5462507
Molecular Formula
C19H21NO4
Molecular Weight
327
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
1
Details
LC Conditions (App ID: 23560)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
Biphenyl
Elution Type:
Gradient
Mobile Phase:
A: 10mM Ammonium Formate in Water (pH unadjusted)
B: 0.1% Formic Acid in Methanol
Gradient Profile:
Step No.Time(min)%A%B
10955
21.27030
31.34555
42.33070
52.4595
62.7595
72.72955
84955
Flow Rate:
1 mL/min
Temperature:
30°C
Detection:
Tandem Mass Spec (MS-MS) (22°C)
Detector Info:
SCIEX 6500 QTRAP

Order Items Used in This Application

Similar Applications
search
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
Reversed Phase
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, EA
Reversed Phase
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
Reversed Phase
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
Reversed Phase
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
Reversed Phase
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
Reversed Phase
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
Reversed Phase
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
Reversed Phase