|Industry Applications|Chemicals and Energy

Chemicals and Energy Solutions

Specialty Chemicals and Fuels Solutions

Phenomenex offers a broad range of flexible GC, LC, and sample preparation products that help you deliver fast, sensitive, and accurate results for raw materials, formulations, simulated distillation, and more.

  • Meet the rigorous requirements of ASTM, EN, and specialized methods
  • Get specialized GC products for fuels analyses
  • Cover your needs with reversed phase, size exclusion (SEC), gel permeation (GPC), and gel filtration (GFC)

Know what you need? Fast track your checkout.

QUICK ORDER
/quick-order
#ffffff00
smooth-scroll-vertical-tabs
3
Zebron ZB-WAX
Enhance resolution and aqueous stability for beter fine chemical testing.
Explore
/products/zebron-gc-columns/zebron-zb-waxplus
#F2F5F9
Zebron ZB-1XT SimDist GC Columns
Improve the efficiency of your simulated distillation analysis by up to 70%.
Explore
/products/zebron-gc-columns/zebron-zb-1xt-simdist
#F2F5F9
Rezex Ion Exclusion Columns
Ion exclusion columns for easy fermentation monitoring.
Explore
/products/rezex-hplc-column
#F2F5F9

Technical Notes

Chemical Industry LC & GC Separation Solutions Guide
View Document
/documents/chemical-industry-lc--gc-separation-solutions-guide
#F2F5F9
An Improved Test Method for Fast Measurement of Polycyclic Aromatic Hydrocarbons (PAHs) in Electronic Components by GC-MS using a Zebron™ ZB-PAH-EU GC Column
View Document
/documents/pfas-and-genx-from-water-by-solid-phase-extraction-and-lc-msms
#F2F5F9
Fast Analysis of Alcohol-Based Sanitizers by GC-FID using Zebron-WAX
View Document
/documents/fast-analysis-of-alcohol-based-sanitizers-by-gc-fid-using-zebron-zb-waxplus-gc-columns
#F2F5F9

Top Tips!

Check out our most commonly asked questions regarding Chemicals and Energy work.

How can I reduce peak fronting in GC?

GC peak fronting can occur when one or more of the compounds injected on the column exceeds the capacity of the liquid phase of the column. The thinner the liquid-phase film, the less of each compound can be retained by the column. To prevent GC peak fronting, reduce the injection volume, increase the split ratio, or inject a less concentrated sample.

How do I alleviate baseline oscillations in GC?

Oscillations in baselines can be problematic, causing increased noise levels as well as interfering with quantitation. Oscillations can sometimes be considered noise, but occur in a pattern that is slower than typical noise. Looking at the frequency and temperature dependence of the oscillations can help distinguish the cause of the disturbance.

Slow, Low Frequency Oscillations

Peaks are independent of the temperature ramp. The cause is likely due to gas pressure fluctuations. In the below instance, the air compressor would pressurize a storage tank which would increase line pressure, resulting in higher flow and cause the signal to rise. Usage decreases the storage tank pressure, causing a dip in pressure and flow. Adding a dual stage regulator to minimize pressure fluctuations will help to minimize the problem.

Fast, Higher Frequency Oscillations

Peaks are evenly spaced and frequency is independent of the temperature ramp. The cause is likely detector related. Baking the detector at the maximum temperature (450 °C for FID) for 30 min to 1 hour may provide temporary relief. For a lasting solution, it may be necessary to physically clean the detector.

Temperature Dependent Oscillations

Peak frequency is temperature dependent. Faster temperature ramps give more frequent peaks as seen below when reaching an isothermal temperature in the middle of the chromatogram. These peaks are due to contamination that is being introduced onto the column, and the column is separating the peaks. The sample or the inlet has been contaminated, likely with siloxanes or hydrocarbons. Changing samples, wash solvents, liner, gold seal, and sometimes the syringe may be required to eliminate the contamination.

Baseline oscillations can affect the signal to noise ratio, and so can excessive column bleed! Extra column bleed can cause increased noise, making it more difficult to quantitate peaks. Consider choosing a low bleed column (such as any Zebron MS Certified column) to reduce noise levels.

Product Finder

Explore the Best Phases for Your Separation Needs

PRODUCT FINDER
/industries/chemicals-and-energy/product-finder
18868,25840

Applications

View All Applications
/resources/application-library#f-phxindustries=Chemicals%20and%20Energy