|Industry Applications|Clinical Research

Clinical Research

From Clinical Sample Preparation to LC-MS Analysis, We Have You Covered

Our team of experts understands the challenges associated with clinical research; starting at the sample itself all the way through separation and analysis. Let us help you boost your throughput and improve your workflows with our portfolio of sample preparation and LC products that are sure to fit your needs.

  • Tackle challenging matrices with our portfolio of clinical sample preparation products
  • Achieve the sensitivity you need with our core-shell LC products
  • Reliably run your methods, day after day, with reproducible LC and sample preparation medias

Know what you need? Fast track your checkout.

Quick Order
/quick-order
#ffffff00
smooth-scroll-vertical-tabs

Overview

Research Specialty Resources Hubs

Industry Spotlight

4
Efficient and Sustainable Clinical Sample Preparation Using Strata SE SLE (TN-1379)
Download
/documents/efficient-and-sustainable-clinical-sample-preparation-using-strata-se-sle
#F2F5F9
A Comprehensive Study on Batch-to-Batch Reproducibility of Strata SE SLE
Download
/documents/a-comprehensive-study-on-batchtobatch-reproducibility-of-strata-se-sle-tn1378
#F2F5F9
Rapid LC-MS-MS Method for Monitoring Bio-Relevant Levels of PFAS in Serum (TN-1325)
Download
/documents/rapid-lcmsms-method-for-monitoring-biorelevant-levels-of-pfas-in-serum-tn1325
#F2F5F9
Quantitation of Pain Panel Analytes from Oral Fluid Utilizing Microelution Solid Phase Extraction Coupled with LC-MS/MS
Download
/documents/quantitation-of-pain-panel-analytes-from-oral-fluid-utilizing-microelution-solid-phase-extraction-co
#F2F5F9
Reducing PFAS Interferences During Human Plasma and Serum Analysis with Accurate Mass Spectrometry (TN-1323)
Download
/documents/reducing-pfas-interferences-during-human-plasma-and-serum-analysis-with-accurate-mass-spectrometry-t
#F2F5F9
LC-MS/MS based Quantification of 47 Therapeutic Drug Monitoring Compounds in Serum: A Simple Sample Preparation Strategy for Efficient Analysis (TN-0159)
Download
/documents/lcmsms-based-quantification-of-47-therapeutic-drug-monitoring-compounds-in-serum-a-simple-sample-pre
#F2F5F9
4
Kinetex Biphenyl
High-efficiency core-shell product (1.7, 2.6, or 5 µm) enhances separation of non-polar and polar compounds using hydrophobic, pi-pi, and dipole-dipole interactions.
Explore
/documents/separation-of-low-level-estrogen-analytes-from-plasma-by-lcmsms-analysis-in-conjunction-with-novum-p
#F2F5F9
Luna Omega C18
Advanced thermally modified (1.6, 3 or 5 µm) particle and bonding provides all purpose C18 selectivity, expanded retention and high batch-to-batch reproducibility.
Explore
/products/luna-omega-hplc-column/luna-omega-c18
#F2F5F9
Strata SE
Interference-free SLE sample prep designed for low-level extractions. Get clean extracts and high recoveries from biological samples
Explore
/products/strata-solid-phase-extraction-products/strata-se-sle
#F2F5F9
Strata-X PRO
New reversed phase polymer with matrix removal technology offers a faster, cleaner way to perform SPE. Learn how to reduce protocol time by at least 40%.
Explore
/documents/steroid-panel-extraction-from-plasma-using-novum-pro-simplified-liquid-extraction-sle
#F2F5F9
4
Simplifying Solid Phase Extraction for Faster and Cleaner Results
View Webinar
/resources/webinars/simplifying-solid-phase-extraction-for-faster-and-cleaner-results
#F2F5F9
Method Development for SPE with Steroids
View Webinar
/resources/webinars/method-development-for-spe-with-steroids
#F2F5F9
LC-MS/MS Drug Analysis Sample Prep Webinar | Phenomenex
View Webinar
/resources/webinars/sample-preparation-strategies-for-lc-msms-analysis-of-drugs-in-difficult-matrices
#F2F5F9
Exploring LC Selectivity Using Steroids in a Clinical Setting
View Webinar
/resources/webinars/exploring-lc-selectivity-using-steroids-in-a-clinical-setting
#F2F5F9

Top Tip

How do you pretreat a whole blood sample for SPE?

A simple pretreatment is to add 10% TCA (trichloroacetic acid) aqueous solution in the ratio of 1:1.Centrifuge and collect the supernatant.  Another simple way to pretreat whole blood is to perform protein precipitation with cold acetonitrile-methanol (85:15) in the ratio of 1:2.  After centrifuging, the supernatant is diluted with solvent appropriate for extraction loading.A more thorough pretreatment is converting whole blood into blood plasma.  Centrifuging anti-coagulated blood gives blood plasma as supernatant.  Blood plasma preparation kits with prepackaged tubes containing an anticoagulant are commercially available.For more information on sample pretreatment for extraction using Strata and Strata-X, please contact us.

I have seen you have a number of different applications for Vitamin D, which ones should I consider?

When attempting to analyze vitamin D, it is important to consider the source of the sample.

That is, if samples are from a biological source the vitamin D is likely to be present as the 25-hydroxyvitamin D3 . The difficulty will be in separation of 25-hydroxy and 3-epi-25-hydroxy vitamin D3, and we have applications specific for this critical pair.If the separation is vitamin D from a food stuff or supplement, it will be present just as Vitamin D3 (cholecalciferol) and this is a much more straightforward separation. We have applications on this as well as other fat-soluble vitamins.

Product Finder

Explore the Best Phases for Your Separation Needs

PRODUCT FINDER
/industries/clinical-research/product-finder
18868,25840,24737

Applications

View All Applications
/resources/application-library#f-phxindustries=Clinical