Luna Omega C18 HPLC Columns

First Choice C18 for Hydrophobic Selectivity

Luna Omega C18 is an excellent first choice for chromatographers who are just starting method development or attempting to improve upon existing chromatographic results with other C18s. With its higher performance potential, excellent retention profile, and greater inertness, the Luna Omega C18 was designed to be the new all purpose UHPLC solution for industries all over the world.

  • Compatible with All Analytical HPLC/UHPLC Systems*
  • Fully Scalable Particle Size UHPLC HPLC Preparative
  • Highest Reproducibility and Batch-to-batch Confidence.

Hydrophobic Selectivity

*Luna Omega analytical columns are compatible with all LC system with standard LC column end-fittings threaded in 10-32. Please contact us at Phenomenex.com/chat for any questions and information about fitting compatibility and any other column internal diameters.

HPLC
53
746
luna-omega-hplc-column
luna-omega-c18
smooth-scroll-vertical-tabs

Order

Overview

Greater Retention and Better Results

Higher efficiency levels in combination with excellent stationary phase coverage and greater particle inert ness, translates to improved separation power for you. Now you can utilize the greater retention of Luna Omega C18 to tackle both easy and difficult separations.

Greater Retention and Better Results

Consistent and Reliable C18 Results

Batch-to-batch and column-to-column, Luna Omega media and columns are designed to be consistent and incredibly accurate tools for your analysis. Each batch and column are quality tested to ensure dependability and reproducibility.

Luna Omega C18

Consistent Reliable Omega C18

Conditions for all columns:

Columns:
Luna Omega 1.6 µm C18
Dimension:
50 x 2.1 mm
Part No.:
00B-4742-AN
Flow Rate:
0.4 mL/min
Temperature:
Ambient
Detection:
UV @ 220 nm
Mobile Phase:
A: Water, B: Acetonitrile
Gradient:
Time (min)
% B
0
20
6
60
6.01
20
8
20

Samples:

  1. Estriol
  2. Prednisolone
  3. Hydrocortisone
  4. Cortisone
  5. Cortisone Acetate
  6. 21-Hydroxycortisone
  7. 17-Hydroxycortisone
  8. Deoxycorticosterone

All Purpose HPLC and UHPLC Selectivity

Strong and focused hydrophobic retention, incredible efficiency and valuable inertness of Luna Omega C18 columns make them an excellent choice for small mixtures of compounds differing in hydrophobicity as well as large mixtures of compounds like drug impurity and degradation profiles and natural products.

Phenols

Phenols Omega

Columns:
Luna Omega 1.6 µm C18
Dimension:
50 x 2.1 mm
Part No.:
00B-4742-AN
Flow Rate:
0.4 mL/min
Temperature:
22 °C
Detection:
UV @ 270 nm
Mobile Phase:
A: 0.1 % Formic Acid in Water, B: 0.1 % Formic Acid in Acetonitrile
Gradient:
Time (min)
% B
0
5
6
50
7
50
7.1
5
9
5

Samples:

1. 3-Hydroxyphenol
2. Phenol
3. 4-Nitrophenol
4. 4-Methylphenol
5. 2-Methylphenol
6. 2,4-Dimethylphenol
7. 1-Naphthol

Synthetic Cannabinoids

Synthetic Cannaboids

Columns:
Luna Omega 1.6 µm C18
Dimension:
50 x 2.1 mm
Part No.:
00B-4742-AN
Flow Rate:
0.3 mL/min
Temperature:
30 °C
Detection:
MS/MS (SCIEX® API 4000™)
Mobile Phase:
A: 0.1 % Formic Acid in Water,  B: 0.1 % Formic Acid in Acetonitrile
Gradient:
Time (min)
% B
0
50
6
100

Samples:

1. JWH-073 Butanoic acid metabolite
2. JWH-073 3-hydroxybutyl metabolite
3. JWH-018 Pentanoic acid metabolite
4. JWH-073 4-hydroxybutyl metabolite
5. JWH-018 4-hydroxypentyl metabolite
6. AM-2201 4-hydroxypentyl metabolite
7. JWH-018 5-hydroxypentyl metabolite
8. AM-694
9. AM-2201
10. JWH-073
11. JWH-018

Samples:

1. 3-Hydroxyphenol
2. Phenol
3. 4-Nitrophenol
4. 4-Methylphenol
5. 2-Methylphenol
6. 2,4-Dimethylphenol
7. 1-Naphthol

Higher Efficiency Compared to Other Fully Porous Particles

Luna Omega 1.6 µm, 3 µm, and 5 µm particle columns provide higher efficiencies compared to other silica C18 columns with fully porous particles of the same size due to the absence of micropores within the particles.

Porous Particles

Conditions for all columns:

Columns:
Luna Omega 1.6 μm C18, ACQUITY BEH 1.7 μm C18
Dimension:
50 x 2.1 mm
Part No.:
00B-4742-AN
Flow Rate:
0.4 mL/min
Temperature:
Ambient
Detection:
UV @ 254 nm
Mobile Phase:
A: 0.1 % Formic Acid in Water,  B: 0.1 % Formic Acid in Acetonitrile
Gradient:
Time (min)
% B
0
5
5
95
6
95
8
5
6.1
5

Samples:

1. Pindolol
2. Chlorpheniramine
3. Nortripytline
4. 3-Methyl-4-nitrobenzoic acid
5. 5-Methyl salicylaldehyde
6. Hexanophenone

25942, 25752, 25436

Applications

View All Applications
/resources/application-library#f-phxphases=C18