HPLC
22
3030
biozenlc-hplc-column
biozen-dsec-7

Biozen dSEC-7

AAV and Large Biomolecule Aggregate Analysis​

Biozen dSEC-7 columns are packed with 700 Å large pore silica coupled with a proprietary hydrophilic diol-type bonded surface chemistry that ensures silica surface interactions are mitigated. Designed with optimized column dimensions, dSEC-7 conserves valuable sample consumption, facilitates faster run times, and maximizes resolution for AAVs and large biomolecule separations.

Robust and reliable aggregate analysis:

  • Baseline resolution of monomer/aggregate species through 700 Å pore size
  • Reduction in sample consumption by up to 90 % compared to traditional SEC columns
  • Reduction in method times by up to 50 % when compared to traditional SEC columns
#ffffff00
smooth-scroll-vertical-tabs

Order

An SEC Column for AAV Aggregate Analysis

Hydrophilic Diol-Type Surface Chemistry

Biozen dSEC-7 columns are packed with large pore silica coupled with a proprietary hydrophilic diol-type bonded surface chemistry that ensures silica surface interactions are mitigated.

Optimized Loading Capabilities

Biozen dSEC-7 offers optimized column dimensions to provide improved resolution and reproducibility at lower sample loads to reduce sample consumption.

Biozen dSEC-7 Features

3
Improved Loading
Improved Loading
dSEC-7 addresses the challenge of aggregate analysis by offering accurate detection and separation with injections as low as 0.5 µL. Unlike traditional methods that demand large sample volumes, dSEC-7 conserves valuable samples, allowing for replicate analyses and ensuring availability for other CQA tests
ACCESS APPLICATION NOTE
/documents/mitigating-high-sample-volume-consumption-in-adenoassociated-virus-aav-aggregate-analysis-using-a--b
#F2F5F9
Mobile Phase Flexibility
Mobile Phase Flexibility
dSEC-7’s particle properties facilitate robust separation of monomer from aggregate species, regardless of which mobile phase best suits your sample. This ensures reproducible results while accommodating unique sample demands, easing the burden of method condition optimization during development.
ACCESS APPLICATION NOTE
/documents/robustness-of-biozen-dsec7-to-mobile-phase-changes-for-the-aggregate-analysis-of-adenoassociated-vir
#F2F5F9
Serotype Versatility
Serotype Versatility
With its robust performance and 700 Å pore size, dSEC-7 effectively resolves monomer from aggregate peaks across various AAV serotypes. This capability is crucial for evaluating appropriate serotype candidates, each varying in its unique tissue and cell tropisms, to ensure desired th
ACCESS APPLICATION NOTE
/documents/adenoassociated-virus-aav-serotype-screen-using-a--biozen-dsec7-size-exclusion-column
#F2F5F9
Instrument Agnostic Performance
Instrument Agnostic Performance
Despite differences in dwell volume and dispersion across various sites and departments, dSEC-7 consistently delivers robust and reproducible performance across commercially available LC instrumentation. This ensures reliable results regardless of variations in equipment, setup, or location.
ACCESS APPLICATION NOTE
/documents/detector-versatility-for-adenoassociated-virus-aav--aggregate-analysis-with-a-biozen-dsec7-column
#F2F5F9
Outperforms Trending Solutions
Outperforms Trending Solutions
dSEC-7 excels in providing superior resolution over market alternatives, particularly when characterizing higher-level aggregates in AAV analysis. Unlike current market solutions with insufficient particle pore size, dSEC-7 ensures accurate and reproducible separation of AAV monomer from aggregates.
ACCESS APPLICATION NOTE
/documents/performance-comparison-of-biozen-dsec-7-sec-column-for-aav-aggregate-analysis
#F2F5F9
Enhanced Detector Flexibility
Enhanced Detector Flexibility
dSEC-7 addresses the challenge of aggregate analysis by offering accurate detection and separation with injections as low as 0.5 µL. Unlike traditional methods that demand large sample volumes, dSEC-7 conserves valuable samples, allowing for replicate analyses and ensuring availability for other CQA tests
ACCESS APPLICATION NOTE
/documents/detector-versatility-for-adenoassociated-virus-aav--aggregate-analysis-with-a-biozen-dsec7-column
#F2F5F9

Biozen dSEC-7 Method Development Webinar

Overcoming Challenges with AAV Aggregate Analysis Using a Novel Size Exclusion Particle

Key Learning Objectives:

  • Best practices for maximizing AAV aggregation separation​
  • How to improve throughput and reduce AAV sample consumption​​
  • Impact of optimizing particle chemistry, pore size and hardware for AAV analysis​​
VIEW NOW
https://discover.phenomenex.com/aav-aggregate-analysis-size-exclusion-webinar?_gl=1*b8rtl6*_gcl_au*MjY2NTg0MDI2LjE3NzE0ODU4MTguMzEzMDgzNTg4LjE3NzMzODI3MzEuMTc3MzM4MjczMA..*_ga*MTAwMTA3ODI3MC4xNzY2MDUyMTE3*_ga_790WGKEF4G*czE3NzQ4ODQyOTckbzMzMiRnMSR0MTc3NDg5MDQ2NCRqMjUkbDAkaDA.*_ga_X15MFH3TKC*czE3NzQ4ODQyOTckbzMyNyRnMSR0MTc3NDg5MDQ2NCRqMjYkbDAkaDEyMzU2MTYxMTg.
#ffffff00