For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.

Luna Omega HPLC/UHPLC LC Columns

Product Information
Brand
World Renowned HPLC Media Reinvented for UHPLC!
Luna Omega high performance HPLC column offers better peak shape, greater separation muscle, and extreme dependability. Luna Omega HPLC columns are available in the following reversed phase selectivities, Omega C18, Omega Polar C18, and Omega PS C18.

World Renowned HPLC Media Reinvented for UHPLC!

The cutting edge thermally modified Luna Omega particle delivers high efficiency, ruggedness, reproducibility, and dependability for a wide range of chromatographic analyses. Luna Omega HPLC and UHPLC columns are built upon more then 20 years of applied knowledge, invention, and customer experience in the manufacture and packing of LC columns. The particle’s novel design and proprietary manufacturing process results in greater particle inertness, a stronger particle morphology, and more consistent porosity.

  • Greater separation muscle and retention
  • Consistent porous structure and elimination of micropores
  • Extreme ruggedness and reproducibility

luna-omega-logo
Luna Omega HPLC/UHPLC LC Columns

Luna Omega Silica

One of the world’s leading HPLC brands, now enhanced for incredible HPLC and UHPLC performance! Luna Omega 1.6, 3, and 5 µm columns culminate 20 years of technological prowess, advancements, and innovation from Phenomenex! With astounding efficiency levels, highly versatile selectivities, and trusted accuracy, Luna Omega columns will take your chromatographic experience to a new level.

Thermal Modified Pore Structure

Material Characteristics

Phase Particle
Sizes (µm)
Pore Size
(Ã…)
Surface
Area (m2/g)
Carbon
Load (%)
pH
Stability
Pressure Limit (Bar) USP Column
Classification
C18 1.6, 3, 5 100 260 11 1.5 – 8.5* 1034/345** L1
PS C18 1.6, 3, 5 100 260 9 1.5 – 8.5* 1034/345** L1
Polar C18 1.6, 3, 5 100 260 9 1.5 – 8.5* 1034/345** L1
Omega SUGAR 3 100 260 2 2.0 – 7.0 345 L8

*pH stability under gradient conditions. pH stability is 1.5-10 under isocratic conditions.
**1.6 μm Luna Omega columns are pressure rated up to 1034 bar and 3 or 5μm are stable up to 345 bar.

Controlled Column Reproducibility

Batch-to-batch and column-to-column, Luna® Omega media and columns are designed to be consistent and incredibly accurate tools for your analysis. Each batch and column are quality tested to ensure dependability and reproducibility.

Quality documents are now digital, find your CQA here. www.phenomenex.com/QD

Application Note 23523
Conditions for all columns:

Column:
Dimensions:
50 x 2.1 mm
Part No.:
Mobile Phase:
A: Water
B: Acetonitrile
Gradient:
Time (min)
0
6
6.01
8
 
% B
20
60
20
20
Flow Rate:
0.4 mL/min
Temperature:
Ambient
Detection:
UV @ 220 nm
Sample:
1. Estriol
2. Prednisolone
3. Hydrocortisone
4. Cortisone
5. Cortisone Acetate
6. 21-Hydroxycortisone
7. 17-Hydroxycortisone
8. Deoxycorticosterone

Scalable from UHPLC to HPLC to PREP

Direct Scalability 1.6 µm to 5 µm

Conditions for all columns:

Column:
Dimensions:
50 x 2.1 mm
Mobile Phase:
A: Water with 0.1% Formic Acid
B: Acetonitrile with 0.1% Formic Acid
Gradient:
Time (min)
0
5
 
% B
5
95
Flow Rate:
0.4 mL/min
Temperature:
Ambient
Detection:
UV @ 254 nm
Sample:
1. Uracil
2. Pindolol
3. Chlorpheniramine
4. Nortriptyline
5. 3-Methyl-4-nitrobenzoic acid
6. 5-Methyl salicylaldehyde
7. Hexanophenone

Scalable from UHPLC to HPLC to PREP

UHPLC, HPLC, Preparative Purification
Comparative separations may not be representative of all applications.

UHPLC Efficiency Comparison

Conditions for all columns:
Dimension:
50 x 2.1 mm
Mobile Phase:
Acetonitrile/Water (65:35)
Flow Rate:
0.5 mL/min
Temperature:
Ambient

Comparative separations may not be representative of all applications.
*Efficiency (plates/meter) comparison is based on peak performance associated with the compound naphthalene for all columns.

Detection:
UV @ 254 nm
System:
ACQUITY UPLC®
Sample: