Phenogel 100 Å GPC/SEC Columns
The Optimal Choice for Aqueous and Mixed Organic Solutions
- Molecular Weight Range: 500 - 6 K
- Recommended for use with small organics
- Wide range of solvent compatibility: packed in tetrahydrofuran (THF); additional shipping solvents (i.e. DMF, Toluene, Chloroform, and others) available on request
- Temperature stable to 140 °C
- Reduce solvent consumption and disposal costs up to 65 % while retaining elution profile with Narrow Bore columns
- Recommended column for USP L21
Order
Applications on Phenogel Fixed Pore 100Å Non-Aqueous GPC/SEC Columns
Polyethylene Glycol 330
00H-0442-K0 (100 Å)
00H-0443-K0 (500 Å)
Sample:
1. dp7 546 MW
2. dp6 458 MW
3. dp5 370 MW
4. dp4 282 MW
5. dp3 226 MW
6. dp2 106 MW
7.dp1 62 MW
Closely Related Hydrocarbons
00H-0442-K0 (100 Å)
00H-0443-K0 (500 Å)
Sample:
1. C40 562 MW
2. C32 450 MW
3. C24 338 MW
4. C20 482 MW
5. C16 226 MW
6. C13 684 MW
The columns were used in tandem to characterize isoprene chain lengths removed from labeled in vitro translation products or cell proteins. The isoprenoids were removed by treatment with Raney nickel and extracted into pentane. The pentane extractable material was hydrogenated over platinum catalyst and injected onto the column. Fractions were collected at 0.5 minute intervals and radioactivity was monitored by liquid scintillation. These saturated hydrocarbon chains were characterized by comparing radioactive peaks to standard retention times.
Isoprenes from In Vitro Translation on Products
00H-0442-K0 (100 Å)
Sample:
1. Squalene C30
(2, 6, 10, 15, 19, 23-Hexamethyltetracosane)
2. Phytane C20
(2, 6, 10, 14-Tetramethylhexadane)
3. Farnesne C15
(2, 6, 10-Trimethyldodecane)
Environmental and Biomonitoring
An application of preparative GPC columns for the automated purification of environmental samples in concordance to the 3640A EPA method. Results shown are the analysis and purification of PAHs by Phenogel GPC columns and the removal of biomaterial matrix interferences that are known to complicate the analysis of PAHs in biological tissues. This method showed that Phenogel 5 µm 100 Å preparative GPC columns efficiently removed lipids from salmon and mussel samples with high recovery of the target 49 PAHs while demonstrating good repeatability and that it could easily be automated for overnight injection.
Oligomer Composition of Over-the-Counter Omega-3 Fish Oil Capsules
Among the variety of over-the-counter (OTC) vitamin and nutraceutical products sold to consumers, fish oils containing omega-3 fatty acids are some of the most widely endorsed by healthcare professionals. Three different OTC fish oil supplements were analyzed by GPC chromatography to determine oligomer composition.
One of the three samples analyzed had an oligomer content that would not have met the acceptance criteria of the Ph. Eur. monograph. Further analysis would need to be performed to characterize the exact composition of omega-3 fatty acids in sample OTC-1.
00H-0442-K0 (100 Å)
00H-0443-K0 (500 Å)