Phenogel 104 Å GPC/SEC Columns
The Optimal Choice for Aqueous and Mixed Organic Solutions
- Molecular Weight Range: 5 K - 500 K
- Recommended for use with resins
- Wide range of solvent compatibility: packed in tetrahydrofuran (THF); additional shipping solvents (i.e. DMF, Toluene, Chloroform, and others) available on request
- Temperature stable to 140 °C
- Reduce solvent consumption and disposal costs up to 65% while retaining elution profile with Narrow Bore columns
- Customize your analysis by coupling different pore size columns
HPLC
69
2549
phenogel-gpc-column
phenogel-10e4a
smooth-scroll-vertical-tabs
Applications on Phenogel Fixed Pore 104 Å Non-Aqueous GPC/SEC Columns
Phenolic Resins
Columns:
Phenogel 5 µm 500 Å x 2, 103 Å, 104 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0443-K0 (500 Å)
00H-0444-K0 (103 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0445-K0 (104 Å)
Solvent:
THF
Flow Rate:
1 mL/min
Temperature:
25 °C
Detection:
Rl
Sample:
Phenolic Aldehyde Resin, MW 500 to 470 K
Polyvinyl Butyral
Columns:
Phenogel 5 µm 500 Å, 103 Å, 104 Å, 105 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0443-K0 (500 Å)
00H-0444-K0 (103 Å)
00H-0445-K0 (104 Å)
00H-0446-K0 (105 Å)
00H-0444-K0 (103 Å)
00H-0445-K0 (104 Å)
00H-0446-K0 (105 Å)
Solvent:
THF
Flow Rate:
1 mL/min
Temperature:
25 °C
Detection:
Differential Refractometer
Injection Volume:
100 µL 0.25 % w/v
Sample:
300,000 MW
Polyethylene Oxide (PEO)
Columns:
Phenogel 10 µm 103 Å, 104 Å, 105 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0444-K0 (103 Å)
00H-0445-K0 (104 Å)
00H-0446-K0 (105 Å)
00H-0445-K0 (104 Å)
00H-0446-K0 (105 Å)
Solvent:
DMF (0.1M LiBr)
Flow Rate:
1 mL/min
Temperature:
50 °C
Detection:
Differential Refractometer
Injection Volume:
100 µL 0.125 % w/v
Sample:
400,000 MW
Polystyrenes (Wide MW Range)
Columns:
Phenogel 10 µm 105 Å, 104 Å, 103 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0446-K0 (105 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
Solvent:
THF
Flow Rate:
1 mL/min
Detection:
Differential Refractometer
Injection Volume:
100 µL 0.25 % w/v
Sample:
1. 1,560,000 MW
2. 260,000 MW
3. 94,000 MW
4. 30,000 MW
5. 6,100 MW
6. 854 MW
7. 146 MW
2. 260,000 MW
3. 94,000 MW
4. 30,000 MW
5. 6,100 MW
6. 854 MW
7. 146 MW
Poly-(α-Methyl Styrene) (Wide MW Range)
Columns:
Phenogel 5 µm 105 Å, 104 Å, 103 Å, 500 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0446-K0 (105 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0443-K0 (500 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0443-K0 (500 Å)
Solvent:
THF
Flow Rate:
1 mL/min
Detection:
Differential Refractometer
Injection Volume:
100 µL 0.25 % w/v
Sample:
1. 680,000 MW
2. 90,000 MW
3. 30,000 MW
4. 6,000 MW
2. 90,000 MW
3. 30,000 MW
4. 6,000 MW
Polymethyl Methacrylates (Wide MW Range)
Columns:
Phenogel 5 µm 105 Å, 104 Å, 103 Å, 500 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0446-K0 (105 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0443-K0 (500 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0443-K0 (500 Å)
Solvent:
THF
Flow Rate:
1 mL/min
Detection:
Differential Refractometer
Injection Volume:
100 µL 0.25 % w/v
Sample:
1. 700,000 MW
2. 107,000 MW
3. 27,000 MW
2. 107,000 MW
3. 27,000 MW
Polybutadienes (Wide MW Range)
Columns:
Phenogel 5 µm 105 Å, 104 Å, 103 Å, 500 Å
Dimension:
300 x 7.8 mm
Part No.:
00H-0446-K0 (105 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0443-K0 (500 Å)
00H-0445-K0 (104 Å)
00H-0444-K0 (103 Å)
00H-0443-K0 (500 Å)
Solvent:
THF
Flow Rate:
1 mL/min
Detection:
Differential Refractometer
Injection Volume:
100 µL 0.25 % w/v
Sample:
1. 420,000 MW
2. 24,000 MW
3. 2,500 MW
4. 500 MW
2. 24,000 MW
3. 2,500 MW