Strata-X-Drug B and Strata-X-Drug B Plus SPE Products

Quick and In-Well Hydrolysis Solid Phase Extraction (SPE)

Proprietary sorbent that is designed and quality controlled for basic drugs of abuse analysis. This sorbent does not require a conditioning/equilibration step to save time and help improve throughput. With Strata-X-Drug B Plus, the hydrolysis step is performed in the well, providing even more time savings and reducing transfer steps.

  • QC Tested for Drug of Abuse
  • No Conditioning or Equilibration Steps Required
#f2f5f9
SP
292
2130
strata-x-solid-phase-extraction-products
strata-x-drug-n
smooth-scroll-vertical-tabs

Overview

General Extraction

Retention Mechanism

Strata-X Drug B Protocol

Strata-X Drug B Plus Protocol

Starting Method

General Urine Pre-treatment Recommendation

  1. Combine urine sample with appropriate buffer.
  2. Add β-Glucuronidase enzyme according to manufacturer’s recommendation (If using Strata-X-Drug B Plus, these steps can be performed in-well).
  3. Incubate for specified amount of time (If using Strata-X-Drug B Plus, pulse vacuum to load solution onto sorbent).
  4. Follow appropriate SPE protocol based on analytes of interest.

Choose Your Analytes

Opiates, 6-MAM, PCP, Amphetamines, Propoxyphene, Healthcare Opiates,

and Methadone*

Marijuana Metabolites
Cocaine Metabolites
Condition
Not Required
Not Required
Not Required
Load
Pre-treated urine sample
Pre-treated urine sample
Pre-treated urine sample
Wash 1
600 µL of 100 mM Sodium acetate buffer (pH 5.0)
600 µL of 100 mM Sodium acetate buffer (pH 5.0)
600 µL of 0.1 N Hydrochloric acid
Wash 2
600 µL Methanol
600 µL of Acetonitrile/100 mM Sodium acetate buffer (pH 5.0) (30:70)
600 µL Methanol
Dry
10 minutes under full vacuum
15 minutes under full vacuum
10 minutes under full vacuum
Elute
2x 300 µL of Ethyl acetate/Isopropanol/
Ammonium hydroxide (70:20:10)
2x 300 µL of Ethyl acetate/Isopropanol
(85:15)
2x 300 µL of Ethyl acetate/Isopropanol/
Ammonium hydroxide (70:20:10)
* Opiates, 6-MAM, PCP, Amphetamines, Propoxyphene, Healthcare Opiates, and Methadone can be extracted simultaneously or separately using the same SPE methodology. Methods are written for 30 mg/well Strata-X-Drug B 96-well plate; however they can be scaled to accommodate smaller or larger sample sizes and sorbent masses.