Recommended Use
Amines, Aroclors, Chemicals, Drugs, EPA Methods (508, 608, 8081, 8141, 8151), Pesticides, Pharmaceuticals, Semi-volatiles, Steroids
   | 
            
             R&D 100 Award-Winning   | 
        
Recommended Use Intermediate polarity with high temperature stability (up to 400 °C) for high boilers, contaminants, carry-overs, and high-temp bakeouts  | 
| Agilent® | Restek® | SGE® | Supelco® | OV® | 
|---|---|---|---|---|
DB®-35  | 
      Rtx®-35 Rtx-35ms  | 
      BPX35 BPX608  | 
		MDN-35 SPB®-35 SPB-608  | 
		OV-11 | 

| 
             Dimension: 
            30 meter x 0.25 mm x 0.25 μm  
             | 
        |
| 
             Injection: 
            Split 20:1 @ 200 °C, 1 µL 
             | 
        |
| 
             Carrier Gas: 
            Helium @ 1.7 mL/min (constant flow) 
             | 
        |
| 
             Oven Program: 
            100 °C to 320 °C @ 30 °C/min for 5 min to  
            340 °C @ 20 °C/min for 5 min to 360 °C @ 20 °C/min for 5 min to 380 °C @ 20 °C/min for 5 min to 400 °C @ 20 °C/min for 5 min to 100 °C @ 30 °C/min for 8 min  | 
        |
| 
             Detector: 
            FID @ 405 °C 
             | 
        

| 
             Part No.: 
            7HG-G025-11 (ZB-35HT Inferno) 
             | 
        |
| 
             Injection: 
            A) Split 50:1 @ 350 °C, 1 µL 
            B) Split 50:1 @ 300 °C, 1 µL  | 
        |
| 
             Carrier Gas: 
            Helium @ 2.1 mL/min (constant flow) 
             | 
        |
| 
             Oven Program: 
            A) 140 °C to 400 °C @ 10 °C/min 
            B) 140 °C to 300 °C @ 10 °C/min  | 
        |
| 
             Detector: 
            A) FID @ 400 °C 
            B) FID @ 320 °C  | 
        |
| 
             Sample: 
            1. Hexadecylamine 
             | 
        |
| 
             Note: 
            Chromatogram is courtesy of
            Northeastern Chemical Company. 
             | 
        

| 
             Column: 
            Zebron ZB-35 Inferno 
             | 
        |
| 
             Dimension: 
            30 meter x 0.25 mm x 0.25 µm 
             | 
        |
| 
             Part No.: 
            7HG-G025-11 
             | 
        |
| 
             Injection: 
            Splitless @ 265 °C, 2 µL 
             | 
        |
| 
             Carrier Gas: 
            Helium @ 1 mL/min (constant flow) 
             | 
        |
| 
             Oven Program: 
            85 °C for 3 min to 320 °C @ 7 °C /min  
            for 8 min  | 
        |
| 
             Detector: 
            MSD @ 280 °C | 
        
Sample: 
        Compounds are 5 ppm 1. Naphthalene 2. Acenaphthylene 3. Acenaphthene 4. Fluorene 5. Phenanthrene 6. Anthracene 7. PCB 28 8. PCB 52 9. PCB 101 10. Fluoranthene 11. Pyrene  | 
    
Sample: 
        12.	PCB 118 13. PCB 153 14. PCB 138 15. PCB 180 16. Benz[a]anthracene 17. Chrysene 18. PCB 194 19. Benzo[b]fluoranthene 20. Benzo[k]fluoranthene 21. Benzo[a]pyrene 22. Indeno[1,2,3-cd]pyrene 23. Dibenz[a,h]anthracene 24. Benzo[g,h,I]perylene  |