Zebron ZB-CLPesticides-1 GC Columns
Drop-In Performance for Chlorinated Pesticides by GC-ECD
Why Pesticide Labs Are Making The Switch
- Guaranteed, direct replacement to Restek® Rtx®-CLPesticides columns
- Resolve multiple chlorinated pesticide classes on one pair with enhanced, fine-tuned selectivity
- Meet requirements for 7 EPA methods by GC-ECD (8081, 8082, 8151, 504, 505, 508, and 552)
- Instantly save on every ZB-CLPesticides column and kit with everyday low pricing
Recommended Applications
Dual-column chlorinated pesticides, herbicides, haloacetic acids (HAAs), EPA Methods (8081, 8082, 8151, 504, 505, 508, and 552)
Order
Overview
Upgrade to Zebron from these similar* phases:
Run 7 EPA Methods On One Column Set
Zebron ZB-CLPesticides-1 and -2 allow you to run multiple methods without changing columns for faster, easier pesticide analysis. Save time and gain flexibility – run multiple pesticide classes on one instrument, on one column pair.
-
Resolve multiple pesticide classes with enhanced, fine-tuned selectivity
-
Meet dual-column requirements for 7 EPA methods by GC-ECD
- 8081: Chlorinated Pesticides
- 8082: Polychlorinated Biphenyls (PCBs)
- 8151: Chlorinated Herbicides
- 504: EDB, DBCP, and TCP
- 505: Organohalide Pesticides
- 508: Chlorinated Pesticides, Herbicides, and Organohalides
- 552: Haloacetic Acids (HAAs) and Dalapo
*Direct replacement: this category indicates an alternative column which will likely give a similar selectivity.
Direct Replacement for Restek Rtx-CLPesticides Phases
You asked for optimized performance for pesticides by GC/ECD detectors, without time-consuming method development. We’ve delivered a direct replacement*! ZB-CLPesticides-1 and -2 provide guaranteed drop-in performance compared to your current Rtx-CLPesticides column set, without the hassle.
Drop-In Results: Real Customer Data, Real Performance
“ I was able to install the ZB-CLPesticides-1 and ZB-CLPesticides-2 columns as a direct replacement for the Restek Rtx-CLPesticides and Rtx-CLPesticides2 columns that I currently use. I made no changes to the method and saw very little difference between the two columns.“
Joanne Foy, Chemist
TriMatrix Laboratories, Inc.
The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization
EPA 8081 Chlorinated Pesticides by GC-ECD
Drop-In Method Performance
ZB-CLPesticides columns combine Zebron high quality with drop-in selectivity. Achieve near-exact elution profiles and run times, without the time-consuming method development and headaches typical of traditional selectivities!
Restek®
Conditions for each method were the same for all columns tested. Comparative separations may not be representative of all applications.
Sample:
Analytes are 250 ng/mL in hexane.
1. 2,4,5,6-TCMX (Surr)
2. α-BHC
3. γ-BHC
4. β-BHC
5. δ-BHC
6. Heptachlor
7. Aldrin
8. Heptachlor epoxide
9. trans-Chlordane
10. cis-Chlordane
11. 4,4’-DDE
12. Endosulfan I
13. Dieldrin
14. Endrin
15. 4,4’-DDD
16. Endosulfan II
17. 4,4’-DDT
18. Endrin aldehyde
19. Endosulfan sulfate
20. Methoxychlor
21. Endrin ketone
22. Decachlorobiphenyl (Surr)
Easily Meet EPA Specifications
The EPA outlines strict performance requirements for compound linearity, percent relative standard deviation (% RSD), and breakdown of DDT and Endrin. The ZB-CLPesticides column pair meets these guidelines, providing accurate data well-suited for your analysis.
Five-Point Calibration Curve at 5, 15, 25, 100, and 250 ng/mL
ZB-CLPesticides-1
% RSD*
ZB-CLPesticides-2
% RSD*
*Calculated using response factors as per EPA guidelines
EPA Method 8082 Polychlorinated Biphenyls (PCBs)
Drop-In Method Performance
ZB-CLPesticides columns combine Zebron high quality with drop-in selectivity. Achieve near-exact elution profiles and run times, without the time-consuming method development and headaches typical of traditional selectivities!
Sample:
Aroclor is 1000 ng/mL and SS and IS
are 100 ng/mL in hexane.
1. Tetrachloro-meta-xylene (TCMX)*
2. Decachlorobiphenyl**
* surrogate standard
** internal standard
Improve Pesticide Analysis & Throughput with Phenova® Certified Reference Materials
Keeping You in Calibration
Phenova CRMs provide lot-to-lot consistency by analytically verifying with internal and external CRMs. This means you will experience minimal trending and fewer out of control calibrations.
- Take control
- Extend your calibration window
- Improve your sample throughput
Consistent Quality
Using ISO/IEC 17025 and ISO Guide 34 compliant quality programs, Phenova CRMs are manufactured and analytically verified, promising you consistency and accuracy each time.
- Get accurate results
- Improve your data quality and analysis
Who Needs to Use Certified Reference Materials?
All environmental labs accredited to ISO/IEC 17025 must use CRMs. Even if your lab does not have this accreditation it still benefits from having a high standard, quality product.