FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Volatile Organic Compounds by Purge and Trap GC-MS on Zebron ZB-624PLUS GC Column at 1ppb
26319
Separation Mode: Improved Performance
Improved Performance
EPA 624
ZB-624plus
GC
Teratogens,Solvents,Anesthetics,Mutagens,Fungicides, Industrial,Carcinogens

Volatile Organic Compounds by Purge and Trap GC-MS on Zebron ZB-624PLUS GC Column at 1ppb

Analytes
11,1,1,2-Tetrachloroethane
21,1,1-Trichloroethane
31,1,2,2-Tetrachloroethane
41,1,2-Trichloroethane
51,1-Dichloroethane
61,1-Dichloroethene
71,1-Dichloropropene
81,2,3-Trichlorobenzene
91,2,3-Trichloropropane
101,2,4-Trichlorobenzene
111,2,4-Trimethylbenzene
121,2,-Dichlorobenzene
131,2-Dibromo-3-chloropropane
141,2-Dibromoethane
151,2-Dichloroethane
161,2-Dichloropropane
171,3,5-Trimethylbenzene
181,3-Dichlorobenzene
191,3-Dichloropropane
201,4-Dichlorobenzene
211,4-Dichlorobenzene-d4 (IS)
221-chloro-2,3-epoxypropane
232,2-Dichloropropane
242-chloro-1,3-butadiene
252-Chlorotoluene
264-Chlorotoluene
27Benzene
28BFB SUR
29Bromobenzene
30Bromochloromethane
31Bromodichloromethane
32Bromoform
33Carbon Tetrachloride
34Chlorobenzene
35Chlorobenzene-d5 (IS)
36Chloroform
37cis-1,2-Dichoroethene
38cis-1,3-Dichloropropene
39Dibromochloromethane
40Dibromofluoromethane SUR
41Dibromomethane
42Ethylbenzene
43Fluorobenzene (IS)
44Hexachlorobutadiene
45Isopropylbenzene
46Isopropyltoluene
47Methylene Chloride
48Naphthalene
49n-Butylbenzene
50n-Propylbenzene
51sec-Butylbenzene
52Styrene
53tert-Butylbenzene
54Tetrachloroethene
55Toluene
56Toluene-d8 SUR
57trans-1,2-Dichloroethene
58trans-1,3-Dichloropropene
59Trichloroethene
60Vinyl Chloride
61Xylene (m+p)
62Xylene (o)
Details
Official Method: EPA 624
GC Conditions (App ID: 26319)
Column:
Part No:
Phase Name:
ZB-624plus
System:
HP 7890 HP GC/MS System (Unknown)
Sample Notes:
Purge & Trap Trap Type K Valve Oven Temp. 140ºC Transfer Line Temp. 140ºC Trap Temp. 35ºC Moisture Reduction Trap (MoRT) Temp. 39ºC Purge Time 11 min Purge Flow 40mL/min Dry Purge Temp. Off Dry Purge Flow 40mL/min Dry Purge Time 1.0 min Desorb Pressure Control On Desorb Pressure 5psi Desorb Time 2.0 min Desorb Preheat Delay 10 sec Desorb Temp. 250ºC Moisture Reduction Trap (MoRT) Bake Temp. 250ºC Bake Temp 210ºC Sparge Vessel Bake Temp. 110ºC Bake Time 6 min Bake Flow 40mL/min Purge and Trap Auto-Sampler EST Analytical Centurion WS Sample Type Water Internal Standard Vol. 5µL Sample Volume 5mL Purge and Trap/GCMS configuration: Recommended trap: 1/3 Tenax 1/3 silica gel 1/3 active carbon Purge Flow: 40ml/min Purge Temp: can be heated up to 40C Preheat time: 2min Purge Time: 11min Dry Purge: 1min Predesorb temp: 180C Desorb Temp: 190C Desorb Time: 2min Bake Temp: 200C Bake Time: 6min
Similar Applications