For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
SPE Background

Strata-X PRO SPE Products

Product Information
Brand
A Rapid Solid Phase Extraction (SPE) Solution
Strata-X PRO SE tubes and 96-well plates allow for streamlined cleanup and efficient recoveries of target analytes from biological, environmental, and food matrices

A Rapid Solid Phase Extraction (SPE) Solution

Strata-X PRO is a new innovative solid phase extraction (SPE) sorbent that offers a faster, cleaner way to extract your samples, completely revolutionizing traditional SPE methods. Strata-X PRO offers improved and rugged polymeric sorbent performance combined with matrix removal technology for a revolutionary solution. With a faster SPE method, it results in at least 40% reduction in time on your SPE protocol. Less steps with no conditioning or equilibration creates a fast SPE method without losing out on the importance of SPE cleaning up your samples.

  • New Polymeric Sorbent with Matrix Removal Technology
  • Provides Unparalleled Reproducibility
  • Easily Process More Samples in Half the Time
  • Reduce Protocol Time by at Least 40% with 3 Step and 2 Step SPE
  • Experience Cutting Edge Performance First Hand
  • High Recoveries without Conditioning or Equilibration

strataxpro-logo
Strata-X PRO Solid Phase Extraction A Rapid Solid Phase Extraction Solution

Available Formats

strata-well-plate
Microelution 96-Well-Plate

strata-x pro well plate
96-Well-Plate

strataXpro-3-tubes
1, 3, and 6mL Tubes

Strata-X PRO Method Compared to Traditional SPE

Identify the SPE Retention Mechanism

SPE Mechanism Analyte Functional Group Sorbent Functional Group  
Reversed Phase
R
hydrocarbon
aromatic
R
hydrocarbon
aromatic
 StrataX PRO A Rapid Solid Phase Extraction Solution

Strata-X PRO Easy Recommended Starting Protocol

Strata-X Pro Tube

Load:
500 µL Pre-treated sample/buffer* (1:1)
Apply 2-5” Hg vacuum until liquid is no longer visible above top frit
Wash:
600 µL 5  % Methanol in Water
Elute:
600 μL 0.1 % Formic acid in Acetonitrile/Methanol (90:10)
Apply 2-5” Hg vacuum for 1 minute
*Select a buffer that maximizes the hydrophobicity of the analytes. For example, if an analyte is basic, dilute with a base.

Strata-X Pro Tube

Load:
1 mL Pre-treated sample/0.1 % Formic acid in Acetonitrile (1:4)
Apply 5” Hg vacuum until all tubes or wells have cleared
Elute:
75 μL Water/0.1 % Formic acid in Acetonitrile (1:4)