FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Extraction of Procaine from Serum using Strata-X-C Microelution & a Kinetex Biphenyl HPLC Column
22983
Separation Mode: Reversed Phase
Reversed Phase
Biphenyl
HPLC
Anesthetics, Local

Extraction of Procaine from Serum using Strata-X-C Microelution & a Kinetex Biphenyl HPLC Column

Analytes
1Procaine
Details
LC Conditions (App ID: 22983)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
Biphenyl
Sample Note:
Strata X-C Elution Plate Protocol Condition 200 µL methanol Equilibrate 200uL water Load 750 µL diluted serum (375 µL plasma diluted 1:1 with 4% phosphoric acid in water) Wash1 200 µL 2% formic acid in water Wash 2 200 µL methanol Elute 25 µL 5% ammonium hydroxide in acetonitrile:methanol(60:40) Inject 1 µL Note: Spiked conc. of analyte was 1 ng/mL serum