FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Documents
Trace Glyphosate Analysis in Drinking Water by LC-Fluorescence Post-Column Derivatization, EPA Method 547 (TN-1231)
Due to the chemical nature of glyphosate, the separation method required to chromatograph glyphosate is ion exchange or ion-exclusion which introduce a different set of challenges. The Rezex™ RFQ Fast Acid ion-exclusion column, allows this analysis to be done in about 15 minutes without the need for column regeneration after each injection. . Additionally, the RFQ Fast Acid column dimensions that was chosen reduces band broadening, which substantially improves the sensitivity of the method.

Trace Glyphosate Analysis in Drinking Water by LC-Fluorescence Post-Column Derivatization, EPA Method 547 (TN-1231)

Due to the chemical nature of glyphosate, the separation method required to chromatograph glyphosate is ion exchange or ion-exclusion which introduce a different set of challenges. The Rezex™ RFQ Fast Acid ion-exclusion column, allows this analysis to be done in about 15 minutes without the need for column regeneration after each injection. . Additionally, the RFQ Fast Acid column dimensions that was chosen reduces band broadening, which substantially improves the sensitivity of the method.
Document Type:
Technical Notes
Brands:
Separation Modes:
Ion-Exclusion