GC
15
395
zebron-gc-columns
zebron-zb-1ht
Zebron ZB-1HT Inferno GC Columns
Robust Results Up to 430 ºC
- First non-metal columns stable to 430 °C
- Provides true boiling point separation for hydrocarbon distillation methods
- Longer lifetime with rugged high temperature, polyimide coated, fused silica tubing
- Low activity, provides good peak shape for acidic and basic samples
- Provides robust column performance for high temperature bake outs
Recommended Use
Diesel Fuel, High Boiling Petroleum Products, High Molecular Weight Waxes, Long-chained Hydrocarbons, Motor Oils, Polymers/Plastics, Simulated Distillation
R&D 100 Award-Winning
Technology for High Temp Testing with advanced polymer bonding technology and specialized high temperature polyimide coating, Zebron Inferno columns offer enhanced performance where other columns fail. See how Inferno columns allow analysts to push a standard analysis up to 430 °C.
Technology for High Temp Testing with advanced polymer bonding technology and specialized high temperature polyimide coating, Zebron Inferno columns offer enhanced performance where other columns fail. See how Inferno columns allow analysts to push a standard analysis up to 430 °C.
smooth-scroll-vertical-tabs
Order
Overview
Upgrade to Zebron from any 100 % dimethylpolysiloxane phase
Agilent®
Restek®
SGE®
Supelco®
DB®-1
Rtx®-1
BP1
SPB®-1
DB-1ht
HP-1
HP-1
Petrocol® 2887
CP-Sil 5 CB
CP-SimDist
Rugged, High-Temperature Performance
Great Separation of High Boiling Hydrocarbons (ASTM D6352)
Column:
Zebron ZB-1HT Inferno
Dimension:
5 meter x 0.53 mm x 0.10 μm
Part No.
Injection:
On-Column @ 43 °C, 0.1 μL
Carrier Gas:
Helium @ 4.4 mL/min (constant flow)
Oven Program:
40 °C for 0.5 min to 430 °C @ 20 °C/min for 10 min
Detection:
FID @ 430 °C
Sample:
1. C10
2. C11
3. C12
4. C13
5. C14
6. C15
7. C16
8. C17
9. Pristane
10. C18
2. C11
3. C12
4. C13
5. C14
6. C15
7. C16
8. C17
9. Pristane
10. C18
11. Phytane
12. C19
13. C20
14. C21
15. C22
16. C23
17. C24
18. C25
19. C26
20. C27
12. C19
13. C20
14. C21
15. C22
16. C23
17. C24
18. C25
19. C26
20. C27
31. C38
32. C39
33. C40
34. C42
35. C44
36. C46
37. C48
38. C50
39. C52
40. C54
32. C39
33. C40
34. C42
35. C44
36. C46
37. C48
38. C50
39. C52
40. C54
41. C56
42. C58
43. C60
44. C62
45. C64
46. C66
47. C68
48. C70
49. C72
50. C74
42. C58
43. C60
44. C62
45. C64
46. C66
47. C68
48. C70
49. C72
50. C74
41. C56
42. C58
43. C60
44. C62
45. C64
46. C66
47. C68
48. C70
49. C72
50. C74
42. C58
43. C60
44. C62
45. C64
46. C66
47. C68
48. C70
49. C72
50. C74
51. C76
52. C78
53. C80
54. C82
55. C84
56. C86
57. C88
58. C90
52. C78
53. C80
54. C82
55. C84
56. C86
57. C88
58. C90
Bake Off Contaminants from Dirty Matrices
Column:
Zebron ZB-1HT Inferno
Dimension:
30 meter x 0.25 mm x 0.10 µm
Part No.
Injection:
On-Column @ 153 °C, 1 µL
Carrier Gas:
Helium @ 1 mL/min (constant flow)
Oven Program:
150 °C to 400 °C @ 14 °C/min for 6 min
Detection:
FID @ 400 °C
Sample:
Sample was 1 % in dichloromethane Mobil® 1 10W-30 Fully Synthetic Motor Oil
Run Versatile Samples
Hydrocarbons from Water by GC-FID DIN EN ISO 9377-2 (DEV H53)
Column:
Zebron ZB-1HT Inferno
Dimension:
15 meter x 0.32 mm x 0.25 μm
Part No.
Injection:
Splitless @ 300 °C, 20 μL
Carrier Gas:
Helium @ 2.0 mL/min (constant flow)
Oven Program:
50 °C for 2 min to 320 °C @ 30 °C/min for 5 min
Detection:
FID @ 330 °C
Sample:
1. Decane (C10)
2. Tetracontane (C40)
16227, 16217, 18153
Applications
BROWSE APPLICATION LIBRARY
Documents
VIEW ALL DOCUMENTS