Zebron ZB-1plus GC Columns
MS Certified “1” Phase
- Very low bleed (MS Certified) phase especially suited to high sensitivity GC-MS
- Extremely inert for active compounds such as drugs, pesticides, or acids and bases
- Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
- Identical selectivity to 100 % dimethylpolysiloxane phases
Recommended Applications:
Acids
Amines
Drugs
EPA Methods (1668)Essential Oils
Flavors & Fragrances
Oxygenates and GROs
PCBsPesticides
Solvent Impurities
Sulfur Compounds (Light)
Diesel Fuel
Order
Overview
Zebron PLUS GC Columns
Improved Inertness, Better Peak Shape, Low Bleed, and Aqueous Stability
Active sites on a GC column’s surface can result in analyte adsorption and degradation, which negatively affect peak shape and response.
To reduce potential surface activity, Zebron PLUS phases (ZB-1PLUS, ZB-5PLUS, ZB-5MSPLUS, and ZB-624PLUS) are designed with a rigorous fused silica deactivation process that improves inertness and peak shapes for troublesome compounds.
Zebron ZB-WAXPLUS is specially designed for 100% aqueous stability, enhanced resolution and better reproducibility.
A. Low bleed phase chemistry
B. Clean, highly inert fused silica surface due to very few active sites
C. Temperature resistant and flexible coating
Equivalent or Better Results
Upgrade to Zebron from any 100 % dimethylpolysiloxane phase:
Lower Overall Column Activity
Activity is a key measure of column quality. Zebron ZB-1PLUS columns are aggressively tested to ensure full deactivation. Below is an example of the aggressive QC test mix we use, notice the low tailing for even the most active compounds like 2-ethylhexanoic acid!
Test Conditions for Zebron ZB-1PLUS
Sample:
1. Decane
2. 2-Ethylhexanoic Acid
3. 4-Chlorophenol
4. Naphthalene
5. Tridecane
6. 1-Undecanol
7. Dicyclohexylamine
8. Pentadecane
Lower Column Bleed
We tested the ZB-1PLUS column bleed profile against other “MS” columns on the market – ZB-1PLUS shows the lowest bleed,
even at temperatures up to 360 °C.
Test conditions were stopped at 350 °C for all competitor columns so as not to cause damage to the stationary phase by exceeding their maximum temperature limit.
Well-Suited for Food & Flavors
Cold Pressed Orange Oil by GC-MS
Sample:
Sample was 10 % in dichloromethane
1. α-Pinene
2. β-Phellandrine
3. β-Myrcene
4. Octanal
5. 3-Carene
6. Limonene
7. Nonanal
8. Linalool
9. cis-Limonene oxide
10. trans-Limonene oxide
11. Citronellal
12. α-Terpineol
13. Decanal
14. Carvone
15. Neral
16. Geranial
17. α-Cubebene
18. β-Cubebene
19. Dodecanal
20. Valencene
21. Cadinene
22. Nootkatone