Axia Preparative LC Columns

Axia Preparative LC Columns help you develop and scale purification methods with more predictable results. Patented self-packing technology creates stable beds that reduce wall effects and downtime. You can scale up throughput without changing particle size while keeping selectivity. Broad media choices and dimensions from 10 mm to 300 mm ID support many prep LC systems and workflows. Custom packing services, brochure downloads, and quote options give you practical support for method development and scale-up.

  • Axia Preparative LC Columns help you make purification method development and scale-up more predictable and reproducible.
  • Axia columns work with major preparative LC systems and come in dimensions from 10 mm to 300 mm ID.
  • The patented self-packing process creates stable packed beds that reduce wall effects and downtime.
  • You can scale up throughput without changing particle size while maintaining selectivity.
  • A wide range of phases, dimensions, and media options helps simplify prep method development and scale-up.

Guaranteed, Longest Lasting Preparative HPLC and SFC Column

Available in over 40 unique achiral and chiral selectivities, Axia advanced preparative column packings and column hardware designs offer several advantages. Unlike traditional preparative HPLC column packing methods, the Axia packing method offers increased sorbent bed density for increased performance and eliminates media bed collapse as a source of premature column failure in preparative HPLC/SFC columns.

Overview

Phenomenex Axia Preparative LC Column Portfolio

Phenomenex offers a diverse portfolio of preparative LC columns that are engineered to meet the wide range of purification challenges faced. Each column brand is designed with unique selectivity, scalability, and loading capacity in mind, ensuring reliable performance across small-scale method development and large-scale production.  Explore our most popular HPLC brands.

Axia Single Axial Compression Step

Axia packed preparative columns involve a single axial compression step, unlike conventional packed preparative columns. The ideal prep HPLC column bed density is custom calculated and automated for each specific media and column size. Computer control of the entire process ensures both proper bed density and column uniformity every time.

Axia™ packed columns produce uniform media bed with intact particles

The highly tuned patented process and hardware eliminates potential decompression ensuring bed stability and optimal packing density. The media found on the inlet frit of the Axia packed column shows no signs of damage unlike the media found on inlet frit of traditionally packed HPLC prep columns.

Traditional packed preparative columns produce non-uniform media beds with sheared and crushed particles

Decompression and then recompression during packing can damage the media and lead to increased column-to-column variability, flow disturbances, and decreased column lifetimes.

Unmatched Column Reproducibility

The automated Axia™ packing system provides feedback control and infinite tuning of packing density for specific media characteristics such as mechanical strength and porosity. An optimum higher bed density can be consistently reproduced column-to-column. This directly translates into consistent efficiency and peak asymmetry measurements and decreases the column variability seen in traditionally packed preparative columns.

Compare Lifetime

Comparative separations may not be representative of all applications. ‡Same linear velocity

Conditions for all columns:

Columns:

Luna 5 µm C18(2) Axia Packed, Waters® XTerra® 5 µm Prep MS C18 OBD™

Dimension:

50 x 21.2 mm (Luna),50 x 19 mm (XTerra)

Flow Rate:

30 mL/min (Luna), 24 mL/min (XTerra)‡

Temperature:

Ambient

Detection:

UV @ 254 nm

Mobile Phase:

A: 0.5 % TFA in Water, B: 0.5 % TFA in Acetonitrile Formic Acid

Gradient:

Linear 95:5 (A/B) to 5:95 (A/B), over 7 min, hold 3 min

Injection Volume:

500 μL

Sample

  1. Triprolidine 1.6 mg
  2. Methacycline 16 mg
  3. Amitriptyline 5.25 mg

Seamless Scalability to Increase Sample Load

Increase sample load without increasing your flow rate by using a longer column. With Axia technology, each preparative column is optimized for:

  • Analytical-like efficiency
  • Long column lifetime
  • High sample load with high surface area media such as Kinetex, Aeris, Gemini, Luna, Luna Omega, or Synergi

Condition:

Flow Rate:

30 mL/min

Gradient:

10 min on 100 mm length column 25 min on,  250 mm length column 5 % to 95 %,  Acetonitrile, 0.5 % TFA

Boost Throughput with Larger Columns

For maximizing load without increasing the run time, consider scaling up to a larger column ID. Axia packed columns provide the three important benefits you need.

  • Reproducible performance across all column diameters
  • Increased throughput without sacrificing purity
  • High efficiency from analytical to preparative

Analytical 50 x 4.6 mm

Dimension:

50 x 4.6 mm

Flow Rate

1.5 mL/min

Sample Load:

0.1 mg in 21 µL DMSO

Axia PREP 50 x 21.2 mm

Dimension:

50 x 21.2 mm

Flow Rate

30 mL/min

Sample Load:

2.1 mg in 420 µL DMSO

Axia PREP 50 x 30 mm

Dimension:

50 x 30 mm

Flow Rate

60 mL/min

Sample Load:

4.2 mg in 840 µL DMSO

Axia PREP 50 x 50 mm

Dimension:

50 x 50 mm

Flow Rate

150 mL/min

Sample Load:

10.5 mg in 2100 µL DMSO

Axia Technology Outperforms Traditional Packing Processes!

Because of the constant pressure placed on the integrated packing piston, Axia packed columns possess the dynamic capability of maintaining a consistent, homogeneous media bed. This results in superior column performance no matter which media selectivity you choose.

Warfarin Chiral Purification in Normal Phase Mode

Column:

Lux 5 µm Cellulose-1

Dimension:

150 x 4.6 mm

Flow Rate:

1 mL/min

Temperature:

Ambient

Mobile Phase:

Hexane / Ethanol (75:25)

Injection Volume:

100 µL

Conditions for both PREP columns:

Column:

Lux 5 µm Celluose-1

Dimension:

150 x 21.2 mm

Flow Rate:

20 mL/min

Temperature:

Ambient

Mobile Phase:

Hexane / Ethanol (75:25)

Injection Volume:

20 mL

42 % Increase in Axia Efficiency

Column (mm)Analytical 150 x 4.6Standard 150 x 21.2Axia 150 x 21.2
Mass Loaded (mg)24040
Resolution*1.52.853.72
Plates (N)117535760
Axia column and packing technology is patented by Phenomenex. U.S. Patent No. 7, 674, 383

Product Finder

Explore the Best Phases for Your Separation Needs

FAQs

Chromatography is the separation of components in a mixture based on their chemical nature. Chromatography can be performed in either liquid (HPLC) or gas (GC) forms. Liquid chromatography, specifically High Pressure Liquid Chromatography (HPLC), involves a stationary phase (sorbent), a mobile phase (liquid) and the analyte or compounds of interest. Analytes or compounds of interest are injected onto an HPLC column (packed with sorbent that contains a variety of chemistries) in mobile phase. As the mobile phase, which is carrying the analyte or compounds of interest, travels across the stationary phase, the analyte or compounds of interest separate from each other as they interact with the stationary phase, each eluting from the column at various times. Gas chromatography (GC) is similar to HPLC in that is utilized with working analytes or compounds of interest that can be vaporized without decomposing. In GC, gas is used instead of a liquid (like in HPLC). As analytes or compounds of interest travel in the gas mobile phase and interact with the stationary phase, eluting at various times.
No. Start with a lower flow rate than normal and pump CO2/MeOH (80/20). For example, if the method calls for 5 mL/min then start the initial flow into the column at 2-3 mL/min and gradually increase over about 20 minutes. AXIA preparative columns will require a longer ramp up to the normal flow rate (at least 30 minutes for a 21.2mm ID). The Hexane/IPA shipping solvent will be easily changed over to SFC mobile phase using this approach.
Below are the part numbers for the appropriate SFC SecurityGuard Holders. These guard cartrudge holders have a Teflon O-rings and a hexnut for wrench tightening. AJ0-8617 SecurityGuard SFC PREP Cartridge Holder Kit for 21.2mm ID SFC Columns AJ0-8618 SecurityGuard SFC PREP Cartridge Holder Kit 30mm ID SFC Columns AQ0-8500 PREP Replacement O-Rings, Teflon® For 15 x 21.2mm SG Holder, Size 2-021 2/Pk AQ0-8501 PREP Replacement O-Rings, Teflon®, For 15 x 30.0mm SG Holder, Size 2-025 2/Pk Please contact us for additional SFC product questions.
If you have a working separation at analytical scale, it is possible to use a simple equation to scale up flow rate, injection volume and mass of sample to allow for a comparable separation at preparative scale. This equation can be used as a guide. Generally it is possible to load more, and loading will normally be increased until the point at which resolution is compromised. F2 = F1 x (L2/L1) X (r2/r1)2 F2 is the new flow rate, F1 the original at analytical scale, L2 the length of the new column, L1 the length of the original, r2 the radius of the new column, r1 the radius of the original. The factor generated by this equation can be applied to flow rate, injection volume and injection mass.
21.2 mm and 30 mm ID AXIA columns are compatible with 1/16 tubing and 10/32 fittings. 50 mm ID AXIA columns are compatible with 1/8 tubing, although they are shipped with reducing unions allowing for the use of 1/16 tubing and fittings.
When injecting samples in a solvent with a higher elutropic strength than the mobile phase, there is always the potential for peak fronting to occur. When working on a preparative scale, this may be unavoidable due to sample solubility issues or simply the fact that the sample solvent cannot be switched. The use of prep frit in front of your Axia column can be beneficial in these cases. It can catch impurities that are not soluble in mobile phase, preventing the column from blocking. Additionally it promotes mixing between the strong sample solvent and the mobile phase, this can help to reduce the fronting effect seen due to the introduction of the sample in the stronger solvent.