FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Lamivudine Related Substances Method per IP Monograph
In this application note, we report the separation of Lamivudine and its related substances using a Luna Omega 5 µm C18 column and a Kinetex 5 µm C18 column according to the Indian Pharmacopoeia (IP) Monograph for Lamivudine, which references use of a 25 cm x 4.6 mm stainless-steel column packed with octadecylsilane bonded to porous silica (5 µm).
Lamivudine Related Substances Method per IP Monograph
In this application note, we report the separation of Lamivudine and its related substances using a Luna Omega 5 µm C18 column and a Kinetex 5 µm C18 column according to the Indian Pharmacopoeia (IP) Monograph for Lamivudine, which references use of a 25 cm x 4.6 mm stainless-steel column packed with octadecylsilane bonded to porous silica (5 µm).