Phree Phospholipid Removal Products
Phree Phospholipid Removal Solutions offer a fast effective way to remove proteins AND phospholipids from plasma samples without negatively affecting the recovery of your target analytes.
One Quick Method, Three Big Advantages:
- Remove Proteins
- Eliminate Phosphopholipids,
- No Method Development
Order
Select a Phase to view products:
Phospholipid Removal
Phospholipid Removal
No Separation Mode
No Phase
Overview
A Simple 2-Step Method
Step 1
Add Plasma
Step 2
Add Organic Solvent + 1% Formic Acid
Step 3
Mix
Step 4
Centrifuge (or apply positive pressure or vacuum for Phree)
Collect Eluent
How Phree Works
Applications
Brochures
Sample Preparation AccessoriesBrochures
Phree Phospholipid Removal SolutionsSupporting Docs
Phree Phospholipid Removal FAQsSupporting Docs
Phree Phospholipid Removal User GuideSupporting Docs
Collection Plate and Sealing Mat Selection GuideTechnical Notes
25-OH Vitamin D2 and D3 from SerumWebinars

Eliminate Ion Suppressing Phospholipids in LC-MS | Phenomenex
View Webinar
Whole Blood: Overcoming Matrix Challenges | Phenomenex
View Webinar
A Simplified Approach to Effective Sample Preparation | Phenomenex
View Webinar
Sample Preparation Techniques Webinar | Phenomenex
View Webinar
Simplify Solid Phase Extraction for Faster, Cleaner Results
View Webinar
LC-MS/MS Drug Analysis Sample Prep Webinar | Phenomenex
View WebinarFAQs
Can I inject my sample from Phree Phospholipid Removal plates/tubes directly onto a reversed phase LC column or will this cause problems?Asked Mar 02, 2022
This is very analyte dependent, if analytes are well retained in the HPLC method, then it is likely that you can inject directly without issues. If analytes elute early in the run, it may be necessary to dilute the sample with water, or a buffer, to weaken the solvent strength of the injection solvent prior to analysis.
How specific is Phree for removing only phospholipids?Asked Jun 15, 2016
Phree is very specific to phospholipids. Analogs of phospholipids, such as long chain fatty acids may also be removed. This is an added benefit for analyses from biological samples. Very few analytes are as hydrophobic as phospholipids so analyte retention on Phree is not a concern. Although there is no method development required to use Phree, it is still important to know what the analytes of interest are to make sure Phree is appropriate for the application.
What are my options for cell lysis for whole blood pretreatment?Asked Mar 23, 2022
• Option 1: Osmotic Breakdown-Add 3 parts D.I Water to one part whole blood sample. Mix/vortex for 3-5 seconds Centrifuge at 3700 rpm for 10 min and collect supernatant • Option 2: Sonication-Sonicate whole blood sample for 15 min at room temperature and centrifuge at 3700 rpm for 10 min and collect supernatant • Option 3: Inorganic salts-Add three parts 0.1M Zinc sulfate/0.1M ammonium acetate solution to one part whole blood sample. Mix/Vortex for 3-5 seconds and centrifuge at 3700 rpm for 10 min and collect supernatant.
What capacity of vacuum pump should I use with an SPE vacuum manifold?Asked Feb 16, 2022
In order to achieve consistent flow rates when running multiple tubes simultaneously it is advisable to use a vacuum pump which can generate a vacuum equivalent to 20" of mercury.