Verex Certified Vial Products

Chromatography Vials, Inserts, and Caps for UHPLC / HPLC / GC / SFC and MS Analysis

Verex HPLC, GC, and autosampler vials offer the lowest ion content possible to reduce sample loss and contamination. From start to finish, Verex HPLC, GC, and autosampler vial and cap products are manufactured to provide high quality, state-of-the-art solutions for your most challenging, sensitive applications. None of the GC/MS or HPLC vials areis placed in the inventory without passing cleanliness and performance testing for consistency resulting in a certified, 100 % defect-free vial that you can trust.

Try Verex Vials in one of the following configurations:

  • Specialty Vials
  • Crimp-Top Vials
  • Screw-Top Vials
  • Snap-Top Vials
  • VOA/ASE Assembled Vial Kits
  • VOA/ASE Assembled Storage Kits

Order

Phase Selected

No Phase

No Phase

Recommended Use

Storage of samples to help maintain sterility and prevent contamination.

Select Attributes:

Accessories Category

Crimp Top Vial

Headspace Vial

Screw Top Vial

Snap Top Vial

Vial Insert

Housing Material

Amber Glass

Clear Glass

Polypropylene

Total Volume

1.25mL

1.4mL

1.5mL

2mL

4mL

6mL

10mL

12.5mL

20mL

21.5mL

40mL

300µL

450µL

475µL

500µL

Vial Certification Level

Cert+

Cert+MSQ

Certified

Vial Dimension (mm)

8 x 40

12 x 32

15 x 45

22 x 38

23 x 46

23 x 75

28 x 57

28 x 95

100 µL

175 µL

200 µL

300 µL

350 µL

450 µL

N/A

Vial Neck Diameter (mm)

5

6

8

9

10

11

13

18

20

24

99

Showing 1-5 of 341 Results

$200.00 USD (200/Pk)

Sign In

$40.00 USD (100/Pk)

Sign In

$290.00 USD (1000/Pk)

Sign In

$45.00 USD (100/Pk)

Sign In

$45.00 USD (100/Pk)

Sign In

Overview

Vials

Verex vials are made of inert, high-purity, chemically stable borosilicate glass to exacting specifications, individually heat-treated to burn off any impurities, then packaged in a cleanroom environment. Choose from crimp, snap, and screw types or mix and match vials and caps to your application.

Vial Compatibility

TypeDescription
8 mm (or 8-425)Compatible with Varian, Shimadzu
9 mm (or 9-425)Compatible with most autosamplers, including Agilent, Thermo Scientific, Waters
10 mm (or 10-425)Compatible with Waters Alliance 2690
11 mmUse with either snap or crimp top seals
13 mm (or 13-425)Compatible with Waters 48 position WISP, Shimadzu

Three Level Certification

Level 1 CertifiedLevel 2 Certified + PLUS (Cert+)Level 3 Certified MSQ (Cert + MSQ) (Mass Spec Quality)

Ultra Clean

Specially designed and treated for mass spectrometry (MS) applications.

⏺

Low Bleed

Special cap / closure processing, treating, and testing for low bleed of residual organics. For high sensitivity GC-MS and LC-MS applications.

⏺⏺

Dimensionally Verified

Machine vision cameras and gauges inspect critical dimensions and tolerances to produce uniform, defect-free products.

⏺⏺

Lot Traceable

Vial and cap packs are 100 % traceable through the manufacturing process. Certificate of Conformance available by lot number upon request.

⏺⏺⏺

Clean Room Packaged

Ensures particulate- and contaminate-free products for clean chromatography.

⏺⏺⏺

Part Number Extension

No Extension

Certificate of Conformance Included; Extension-C

Certificate of

Conformance Included; Extension-M

Part Number Example

AR0-8952-13

AR0-8952-13-C

AR0-8952-13-M

How to Choose the Right Chromatography Vial

Selecting the appropriate chromatography vial is essential for ensuring accurate and efficient analytical results. Here are the key factors to consider:

1. Vial Closure Style

  • Screw Thread Vials: Ideal for HPLC and LCMS analyses due to their ease of use and compatibility with autosamplers. They are commonly used for storing standards and are preferred when frequent opening and closing are required.
  • Crimp Vials: Best for gas chromatography (GC) applications, especially when sample evaporation or tamper-proof closures are concerns. They provide a secure seal but require a crimper tool for closure.
  • Snap Top Vials: Convenient for lab technicians, these vials are suitable for HPLC and LCMS analyses. The closure is pressed down to create a seal, offering ease of handling.

2. Vial Size and Volume

  • 2mL Autosampler Vials: Most commonly used for standard applications.
  • Micro Inserts: Useful for limited sample volumes, available in tapered or flat-bottom designs to optimize sample recovery.
  • High-Recovery Vials: Suitable for re-injections when large sample volumes are needed.

3. Material

  • Glass Vials: Type 1 borosilicate glass is preferred due to its inert properties, minimal pH shift, and resistance to leaching. Verex clear glass vials are made from 33-expansion Type 1 borosilicate glass (USP Type I, Class A), offering excellent chemical resistance and clarity for visible sample monitoring. Amber glass vials, made from 51A Type 1 borosilicate glass, are recommended for protecting light-sensitive samples.
  • Plastic Vials: Polypropylene (PP) vials are economical and compatible with certain solvents but unsuitable for others. PP vials are recommended for specialty applications such as PFAs analysis
  • Specialized cap materials like polyethylene (PE) and TPX polymethylpentene offer unique properties such as chemical resistance and transparency. Additionally, septa are available in various materials—including PTFE, silicone, and rubber—to suit different analytical requirements and ensure chemical compatibility.

4. Compatibility

  • By verifying the vial size, cap type (screw, snap or crimp) and required septa configuration (standard or pre-slit), this ensures the vial matches the specific autosampler model used in your laboratory.
  • By carefully evaluating these factors based on your specific application requirements, you can select the most suitable chromatography vial to optimize your workflow and analytical results.
  • Start strong with Verex vials for reliable performance, reproducibility, and accuracy. Experience first-class quality from purchase to results.

FAQs

First, you need to choose a column that has a very thick stationary phase, such as a 0.25mm ZB-624plus™ column with a 1.4 micron film thickness. Then you need to increase your split ratio, so you don’t send too much analyte onto the column. Also, start the run at a lower temperature, like 30 or 35°C, to provide enough focusing time for on-column separation. Finally, for the low boiling analytes, you should back off a bit on the flow rate.
"Convenience kit" refers to the packaging. Our Verex vial and cap kits come in a carrier box that is designed with a complementary integrated vial and cap product dispenser. To learn more about Verex's packaging, this document explains the box's features, how to use it, and additional types of boxes.
There are many potential sources and solutions: Put caps with filters or sorbent traps on your HPLC mobile phase bottles and solvent waste receptacles; don’t leave residual acetonitrile in pipette barrels; do all your potency extractions and standard preparations in a fume hood; and if you are using a triple quad MS for pesticide analysis, don’t discharge the vacuum exhaust from the ionization source into the lab.
Pressure is released at 3.0 +/- 0.5 Bar (1 Bar = approximately 14.6 PSI) The pressure release will split and vent to prevent the seal and vial from breaking. This prevents instrument down time and provides added lab safety Only use pressure release for high temperature work For the highest quality vial and cap products, we recommend Verex. Our vials and caps are manufactured to provide high quality, state-of-the-art solutions for your most challenging, sensitive applications.
The conical inserts without the bottom spring are a more economical option, however, the inserts with the bottom spring are the best option to ensure the insert runs perpendicular in the vial and not hit the needle.
These poly/steel caps are designed for automated applications and instruments using a magnetic sample transport systems.