Chromatography is the separation of components in a mixture based on their chemical nature. Chromatography can be performed in either liquid (HPLC) or gas (GC) forms. Liquid chromatography, specifically High Pressure Liquid Chromatography (HPLC), involves a stationary phase (sorbent), a mobile phase (liquid) and the analyte or compounds of interest. Analytes or compounds of interest are injected onto an HPLC column (packed with sorbent that contains a variety of chemistries) in mobile phase. As the mobile phase, which is carrying the analyte or compounds of interest, travels across the stationary phase, the analyte or compounds of interest separate from each other as they interact with the stationary phase, each eluting from the column at various times. Gas chromatography (GC) is similar to HPLC in that is utilized with working analytes or compounds of interest that can be vaporized without decomposing. In GC, gas is used instead of a liquid (like in HPLC). As analytes or compounds of interest travel in the gas mobile phase and interact with the stationary phase, eluting at various times.

This is quite a challenge as many of the products that we use, including our solvents, reagents, glassware, sample prep, and LC instrumentation can have PFAS background. Some general tips are to clean all equipment prior to, and after each use, make sure your reagent water, solvents such as methanol and ammonium hydroxide, are as PFAS free as possible. You may have to inquire from your vendor for details or if they can have some guarantee on background levels. There can also be PFAS in disposable plastics such as pipette tips and filters. Some methods recommend baking glassware, deterrent washing and rinsing with clean water, and proper storage for air drying. You can also implement a pre-rinse procedure using methanol with 0.1% ammonium hydroxide, toluene, and methanol. If you are using automated sample preparation, rinse the system with the same solvents. The LC pump should have a delay column between the pump and the autosampler as Teflon seals are common in LC systems. It’s advisable to review validated method guidance which often provide more detail on dealing with interferences within your lab, your system, and also within samples.

No. Start with a lower flow rate than normal and pump CO2/MeOH (80/20). For example, if the method calls for 5 mL/min then start the initial flow into the column at 2-3 mL/min and gradually increase over about 20 minutes. AXIA preparative columns will require a longer ramp up to the normal flow rate (at least 30 minutes for a 21.2mm ID). The Hexane/IPA shipping solvent will be easily changed over to SFC mobile phase using this approach.

To safely transfer a Lux column from normal phase to polar organic or reverse phase conditions, flush the column with methanol:ethanol 9:1 (V/V) as transition solvent at a flow rate of 0.5 mL/min. First, flush the column with at least ten column volumes (i.e. 25 mL for a 250 x 4.6 mm i.d. column or 15 mL for a 150 x4.6 mm i.d. column) to completely remove the initial mobile phase. When the column has been flushed, equilibrate the column with at least ten column volumes of the polar organic or reverse phase solvent mixture to condition the column. In addition, when the buffer salt additive of the reverse phase mobile phase is insoluble in methanol/ethanol, flush the column briefly with water before switching to the buffered mobile phase. When the column has been flushed equilibrate the column with at least ten column volumes with the reverse phase solvent mixture. To safely transfer a column from polar organic to normal phase conditions flush the column with at least ten column volumes of methanol:ethanol 9:1 (V/V) as transition solvent at a flow rate of 0.5 mL/min. When the column has been flushed with methanol/ethanol equilibrate the column with at least ten column volume of the normal phase solvent mixture to condition the column. We do not recommend switching from reverse phase mode back to normal phase mode.

Make up a 1 Liter solution of 5 mM Ammonium Bicarbonate and mix well. Transfer to a larger flask or beaker and follow the procedure. The solution will easily get to pH 9 with a small amount of concentrated Ammonium Hydroxide. In order to get to pH 11 you should expect to add an amount of concentrated Ammonium Hydroxide around 5-10% of the total volume of your solution. For example if you were to make a 1 Liter solution of 5 mM Ammonium Bicarbonate then expect to add as much as 50-100 mL of concentrated Ammonium Hydroxide.

To safely transfer a column from normal phase to SFC, we recommend conditioning directly to 80:20 CO2:co-solvent (typically methanol) at a low pressure, increasing as the pressure stabilizes. You may also start with 100% CO2, considering the small amount of isopropanol (10%) in the shipping solvent is enough to overcome any concerns of straight CO2 displacement of straight hexane. 80:20 CO2:methanol is the equilibration solvent we use in our independent SFC analyses.

Non-compatible solvents are DMSO, DMF, DCM, Acetone, THF, Ethyl acetate and any solvent capable of dissolving the polysaccharide derivative.

Chiral separations with Lux and Chirex are dependent on the nature of the aromatic groups in the chiral compounds of interest and the distance between the aromatic functionality and chiral center in the analyte. Generally, the closer the aromatic group is to the chiral center in a chiral compound the easier it is to separate it’s enantiomers and separations of chiral compounds where the chiral center is 4 or more atoms away from the aromatic ring are uncommon if not impossible. Stationary phases are most effective when the distances between the aromatic group and chiral center are the same in the chiral compound of interest. If the aromatic group of the compound has electron withdrawing groups like halogens or oxygen containing functionality, it will be more electron deficient and will interact more effectively with electron rich aromatic groups in the stationary phase (generally unsubstituted or with electron donating alkyl groups).

Lux columns are interchangeable between normal phase, polar organic, reversed phase, and SFC modes. Additionally, while Lux columns were designed for chiral separations they can be used under the same separation modes as well as HILIC for achiral separations.